PEP#: 215
TITLE: Remove old schemas

DESCRIPTION:

Removing old, unneeded schema files from the repository:

CIM 2.7
CIM 2.7.1 Preliminary
CIM 2.8 Preliminary
CIM 2.9 Preliminary

// ===================================================================
// Title:       System Diagnostics 2.8
// Filename:    System28_Diagnostics.mof
// Version:     2.8
// Release:     Preliminary
// Date:        08/18/2003
// ===================================================================
// Copyright 1999-2003 Distributed Management Task Force, Inc. (DMTF).
// All rights reserved.
// DMTF is a not-for-profit association of industry members dedicated
// to promoting enterprise and systems management and interoperability.
// DMTF specifications and documents may be reproduced for uses
// consistent with this purpose by members and non-members,
// provided that correct attribution is given.
// As DMTF specifications may be revised from time to time,
// the particular version and release date should always be noted.
// 
// Implementation of certain elements of this standard or proposed
// standard may be subject to third party patent rights, including
// provisional patent rights (herein "patent rights"). DMTF makes
// no representations to users of the standard as to the existence
// of such rights, and is not responsible to recognize, disclose, or
// identify any or all such third party patent right, owners or
// claimants, nor for any incomplete or inaccurate identification or
// disclosure of such rights, owners or claimants. DMTF shall have no
// liability to any party, in any manner or circumstance, under any
// legal theory whatsoever, for failure to recognize, disclose, or
// identify any such third party patent rights, or for such party's
// reliance on the standard or incorporation thereof in its product,
// protocols or testing procedures. DMTF shall have no liability to
// any party implementing such standard, whether such implementation
// is foreseeable or not, nor to any patent owner or claimant, and shall
// have no liability or responsibility for costs or losses incurred if
// a standard is withdrawn or modified after publication, and shall be
// indemnified and held harmless by any party implementing the
// standard from any and all claims of infringement by a patent owner
// for such implementations.
// 
// For information about patents held by third-parties which have
// notified the DMTF that, in their opinion, such patent may relate to
// or impact implementations of DMTF standards, visit
// http://www.dmtf.org/about/policies/disclosures.php.
// ===================================================================
// Description: The System Model defines system related management
//              concepts. This file defines the specific concepts for
//              Diagnostics.
// 
//              The object classes below are listed in an order that
//              avoids forward references. Required objects, defined
//              by other working groups, are omitted.
// ==================================================================
// Change Log for 2.8
// CR947 - Add new record types
// CR945 - Change description of ResultPersistence to apply to LogRecord
// CR944 - IsSynchronous DiagnosticTest Characteristic and Miscellaneous
//          cleanup related to PercentOfTestCoverage and IsPackage
// CR937  - Localization
// CR946 - Deprecate DiagnosticResult and add needed
//        properties to DiagnosticServiceRecord
// CR939 - Add verbosity setting for result messages
// CR1020 - Promote "Test" associations to "Service"
// CR1041 - Add Help service
// CR1091 - Cleanup of RunDiagnostic methods
// CR1092  - Move HelpService to new Core28_Help from
//           System28_Diagnostics
// CR1125 - Rename Verbosity to TestResultLevel since it is a
//          corollary of TestWarningLevel.  Clean up descriptions
//          in LogOptions.
// CR1126 - DiagnosticServiceRecord vs. DiagnosticSettingRecord
// CR1130 - DiagnosticsServiceCapabilities model correspondance
//          corrections
// 
// Changes to bring forward from final
// CR726/CR1072 - Add LogOptions, OtherLogOptionDescriptions to
//         DiagnosticSetting and DiagnosticResult
//         Deprecate ReportSoftErrors and ReportStatusMessages from
//         DiagnosticSetting and DiagnosticResult
// CR764/CR1076 - Add DiagnosticService
//       - Change subclassing of DiagnosticTest from Service to
//         DiagnosticService
//       - Deprecation DiagnosticTest.ResourcesUsed and DiagnosticTest.
//         IsInUse
//       - Fix the Class Name in the ModelCorrespondence string for
//         DiagnosticTest.OtherCharacteristicDescription
// CR765/CR1077 - Update the the DiagnoticTest and DiagnosticResults
//         LogOptions property
//       - Modify the description of DiagnosticResults.TestResults
// CR779/CR1073 - Add DiagnosticService.RunDiagnostic()
//       - Deprecate DiagnosticTest.RunTest()
//       - Deprecate DiagnosticTest.DiscontinueTest()
//       - Update class description for DiagnosticTest
// CR780/CR1074 - Add DiagnosticServiceCapabilities
// CR781/CR1075 - Add DiagnosticServiceRecord
// CR887/CR1078 - Fix the DiagnosticService.RunDiagnostic return range
// for
//         Method Reserved.
// CR888/CR1079 - Correct DateTime format in the description of
//         DiagnosticResult.TestResults
// CR889/CR1080 - For consistency change the deprecation statement in
//         RunTest to reference the class where the RunDiagnostic
//         is defined (DiagnosticService).
// 
// Change Log for v2.7 Final
// CR1010 - Update DiagnosticResult.TestResults Description
//          related to datetime
// CR965 - Update description for DiagnosticTestForMSE
// CR973 - Remove Experimental from
//         DiagnosticSetting.LoopControlParameter
//         DiagnosticSetting.LoopControl
//         DiagnosticSetting.OtherLoopControlDescription
//         DiagnosticSetting.ResultPersistence
//         DiagnosticResult.ErrorCode
//         DiagnosticResult.ErrorCount
//         DiagnosticResult.LoopsFailed
//         DiagnosticResult.LoopsPassed
//         DiagnosticResult.LoopControlParameter
//         DiagnosticResult.LoopControl
//         DiagnosticResult.OtherLoopControlDescription
//         DiagnosticResult.ResultPersistence
//       - Move forward with the deprecations
//         DiagnosticResult.IsPackage
//         DiagnosticTest.IsinUse
//         DiagnosticTest.ResourcesUsed
//         DiagnosticResultInPackage
//         DiagnosticTestInPackage
//         DiagnosticTest.RunTest
//         DiagnosticSetting. and DiagnosticResult.ReportSoftErrors
//         DiagnosticSetting. and DiagnosticResult.ReportStatusMessages
//       - Hold off the rest of the Diagnostic deprecations and
//         experimental classes and properties until 2.8 (this
//         includes DiagnosticService, DiagnosticServiceRecord and
//         DiagnosticServiceCapabilities)
// 
// Change Log for v2.7
// CR725 - Add the following 3 properties LoopControlParameter,
//         LoopControl, and OtherLoopControlDescription to
//         DiagnosticSetting and DiagnosticResult
// CR749 - Deprecate DiagnosticTestInPackage, DiagnosticResultInPackage,
//         and DiagnosticResult.IsPackage
// CR766 - Add the following properties to DiagnosticResults:
//         ErrorCode, ErrorCount, LoopsFailed, LoopsPassed
// CR778 - Add property ResultPersistence to DiagnosticSetting and
//         DiagnosticResults
// ===================================================================

#pragma locale ("en_US")


// ==================================================================
// DiagnosticSetting
// ==================================================================
   [Version ("2.7.1000"), Description (
       "Specific diagnostic test parameters and execution instructions "
       "are defined by subclassing and/or instantiating the "
       "DiagnosticSetting object.  To provide more detailed Settings "
       "for a type of test (i.e., additional properties), subclassing "
       "is appropriate.  When only the generic Setting information is "
       "required, instantiation of the Diagnostic Setting class may suffice.\n"
       "Data from DiagnosticSetting is captured in DiagnosticResult.  "
       "When RunTest starts execution the settings, which are time "
       "sensitive, should be evaluated and captured.  This is "
       "suggested since the DiagnosticSetting object can be modified "
       "at any time, and therefore the current test settings could be "
       "lost.") ]
class CIM_DiagnosticSetting : CIM_Setting {

      [Key, Override ("SettingID"), Description (
          "The identifier by which the DiagnosticSetting object is "
          "known and uniquely named.  One possible naming scheme is to "
          "name the SettingID using the DiagnosticTest's CreationClass "
          "Name and DiagnosticName, plus a GUID (Globally Unique IDentifier).\n"
          "Note that at an enterprise level, there is typically not a "
          "one to one mapping between a DiagnosticSetting and all "
          "copies of the DiagnosticTest.  The proposed naming "
          "convention will scale to the entrprise level."), 
       MaxLen (256) ]
   string SettingID;

      [Write, Description (
          "Sets the level of warning messages to be logged.  A client "
          "MUST only select a TestWarningLevel that is supported in "
          "the DiagnosticServiceCapabilities.  This property is used "
          "in conjunction with specifying the 'Warnings' value in "
          "LogOptions.  If for example no warning information is "
          "required, the level would be set to \"No Warnings\" "
          "(value=0).  Using \"Missing Resources\" (value=1) will "
          "cause warnings to be generated when required resources or "
          "hardware are not found.  Setting the value to 2, \"Testing "
          "Impacts\", results in both missing resources and 'test "
          "impact' warnings (for example, multiple retries required) "
          "to be reported."), 
       ValueMap {"0", "1", "2", "3"}, 
       Values {"No Warnings", "Missing Resources", "Testing Impacts",
          "All Warnings"}, 
       ModelCorrespondence { 
          "CIM_DiagnosticServiceCapabilities.SupportTestWarnings",
          "CIM_DiagnosticSetting.LogOptions"} ]
   uint16 TestWarningLevel;

      [Experimental, Write, Description (
          "The LogOptions property indicates that particular types of "
          "test message SHOULD be logged.  Each of these log options "
          "can co-exist with the others.  Note that the default "
          "behavior is for the option to be off/disabled.\n"
          "The following text briefly summarizes the various log options:\n"
          "* \"Unknown\" (value = 0)\n"
          "* \"Other\" (value = 1): Details in the corresponding "
          "OtherLogOptionsDescription entry.\n"
          "* \"Test Errors\" (value = 2): Enable sending errors "
          "related to the element(s) under test.\n"
          "* \"Soft Errors\" (value = 3): Enable sending errors "
          "related to the running of the test.  Examples of soft "
          "errors are: 'not enough memory', 'driver IOCTL not "
          "implemented', or 'known defect'.\n"
          "* \"Status\" (value = 4): Enables sending status messages.  "
          "Examples of status messages are reports of state "
          "information for the test, driver, device, or system.\n"
          "* \"Warnings\" (value = 5): Enables sending warning "
          "messages.  The TestWarningLevel property specifies the "
          "level of warnings to be logged.\n"
          "* \"Hardware Configuration\" (value = 6): Enables sending "
          "messages that contain information about the hardware "
          "configuration under test.  For example the vendor, version, "
          "and location information.  The format and contents of this "
          "property is element dependent.  Examples are: SCSI ID, "
          "LPTx, PCI Slot Number, Dimm#.\n"
          "* \"Debug\" (value = 7): Enables sending debug messages.  "
          "These messages are vendor specific.\n"
          "* \"Statistics\" (value = 8): Enables sending statistics "
          "messages.  An example of statistics would be packets sent "
          "per second.\n"
          "* \"Actions\" (value = 9): Enables sending corrective "
          "action and instructional messages to guide service "
          "personnel.  For example, a numbered list of steps to take "
          "when it has been determined that a device needs to be fixed "
          "or replaced.  Another example would be a prioritized list "
          "of suggested actions to take to isolate a failure.  When "
          "ordering steps or prioritizing actions a number should "
          "proceed the text.  Ex: '1) Do this first 2) next'\n"
          "* \"Software Configuration\" (value = 10): Enables sending "
          "messages that contain information about the software stack "
          "needed to reproduce the test's runtime environment.  For "
          "example, the name and version of all the critical software "
          "elements controlling the device under test.  Each "
          "configuration message SHOULD have the following common "
          "format: Element name; element type; manufacturers name; "
          "version.  Ex: 'Miniport driver; SCSI; Intel; 'Version 1.2'.\n"
          "* \"Subtests\" (value = 11): Enables sending a test summary "
          "report message upon completion of each subtest and each "
          "loop iteration.  These summary reports SHOULD state whether "
          "the individual subtest or iteration passed or failed and "
          "list relevant error codes and respective error counts.\n"
          "* \"References\" (value = 12): Enables sending a message "
          "that records the keys of the element under test.\n"
          "* \"Results\" (value = 13): Results that do not fall into "
          "any other specific category are included here.  This value "
          "will generally be included.  The TestResultLevel property "
          "specifies the level of results to be logged.\n"
          "* \"Result Summary\" (value = 14): This value calls for a "
          "summary result to be generated, usually associated with a "
          "looping diagnostic.\n"
          "\"Setting Data\" (value=15) will cause the data contained "
          "in this class to be logged."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6", "7", "8", "9",
          "10", "11", "12", "13", "14", "15" }, 
       Values {"Unknown", "Other", "Test Errors", "Soft Errors",
          "Status", "Warnings", "Hardware Configuration", "Debug",
          "Statistics", "Actions", "Software Configuration",
          "Subtests", "References", "Results", "Results Summary",
          "Setting Data"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticSetting.OtherLogOptionsDescriptions",
          "CIM_DiagnosticServiceCapabilities.LogOptions"} ]
   uint16 LogOptions[];

      [Experimental, Write, Description (
          "Provides additional information regarding the types of test "
          "messages that are logged when the property LogOptions "
          "includes the value 1 (\"Other\")."), 
       ModelCorrespondence {"CIM_DiagnosticSetting.LogOptions"} ]
   string OtherLogOptionsDescriptions[];

      [Deprecated {"CIM_DiagnosticSetting.LogOptions"}, Write, 
       Description (
          "When this flag is true, the diagnostic test will report "
          "'soft errors'.  In this context, a soft error is a message "
          "from the diagnostic reporting a known defect in the "
          "hardware or driver configuration, or execution "
          "environment.  Examples are: 'Not enough memory', 'Driver "
          "IOCTL not implemented', 'Video RAM compare failed during "
          "polygon fill test (A known defect in the video chipset)', "
          "etc.") ]
   boolean ReportSoftErrors;

      [Deprecated {"CIM_DiagnosticSetting.LogOptions"}, Write, 
       Description (
          "When this flag is true, the diagnostic test will report "
          "'status messages'.  In this context, a status message "
          "indicates that the diagnostic code is at a checkpoint.  "
          "Examples are: \"Completion of phase 1\", \"Complex "
          "pattern\", etc.") ]
   boolean ReportStatusMessages;

      [Write, Description (
          "When this flag is true, the test will halt after finding "
          "the first error.") ]
   boolean HaltOnError;

      [Write, Description (
          "When this flag is true, the test software should attempt to "
          "run in an accelerated fashion either by reducing the "
          "coverage or number of tests performed.") ]
   boolean QuickMode;

      [Write, Description (
          "Requests the diagnostic software to reduce test coverage to "
          "the specified percentage.  For example, a hard drive scan "
          "test could be asked to run at 50%.  The most effective way "
          "to accomplish this is for the test software to scan every "
          "other track, as opposed to only scanning the first half of "
          "a drive.  It is assumed that the effectiveness of the test "
          "is impacted proportional to the percentage of testing "
          "requested.  Permissible values for this property range from "
          "0 to 100.\n"
          "This property may not be applicable to all tests.  If it "
          "can be set for a test, the value 7 (\"Supports PercentOf "
          "TestCoverage\") should be entered into the DiagnosticTest's "
          "Characteristics array."), 
       Units ("Percent"), MinValue (0), MaxValue (100), 
       ModelCorrespondence 
          {"CIM_DiagnosticServiceCapabilities.SupportedServiceModes"} ]
   uint8 PercentOfTestCoverage;

      [Write, Description (
          "Array entries contain parameters corresponding to entries "
          "in the LoopControl array, limiting the number of times a "
          "test should be repeated with a single invocation of RunTest "
          "by a CIM client."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence {"CIM_DiagnosticSetting.LoopControl"} ]
   string LoopControlParameter[];

      [Write, Description (
          "LoopControl, used in conjunction with LoopControlParameter, "
          "sets one or more loop control mechanisms that limits the "
          "number of times a test should be repeated with a single "
          "invocation of RunTest by a CIM client.  There is an "
          "array-positional correspondence between LoopControl entries "
          "& LoopControlParameter entries.  The entries in these "
          "coupled arrays of loop controls can be used in a logical OR "
          "fashion to achieve the desired loop control.  For example, "
          "if a client wants to loop a test 1000 times, but quit if a "
          "timer runs out, it could set both controls into the "
          "LoopControl array as two separate entries in each array.  "
          "The looping test will terminate when the first of the two "
          "ORed conditions are met.\n"
          "The descriptions for each loop control are given below:\n"
          "Unknown/Default (= 0)\n"
          "Other (= 1) : Additional detail may be found in OtherLoopControlDescription.\n"
          "Continuous (= 2) : The corresponding LoopControl Parameter "
          "is ignored and the test will execute continuously.  Tests "
          "that use this control should also support DiscontinueTest.\n"
          "Count (= 3) : The corresponding LoopControlParameter is "
          "interpreted as a loop count (uint32), indicating the number "
          "of times the test should be repeated with a single "
          "invocation of RunTest by a CIM client.\n"
          "Timer (= 4) : The corresponding LoopControlParameter is "
          "interpreted as an initial value (uint32) for a test loop "
          "timer, given in seconds.  The looping is terminated when "
          "this timer has lapsed.\n"
          "ErrorCount (= 5) : The corresponding LoopControl Parameter "
          "is interpreted as an error count (uint32).  The loop will "
          "continue until the number of errors that have occurred "
          "exceeds the ErrorCount.  Note: the ErrorCount only refers "
          "to hard test errors; it does not include soft errors or "
          "warnings."), 
       ValueMap {"0", "1", "2", "3", "4", "5"}, 
       Values {"Unknown/Default", "Other", "Continuous", "Count",
          "Timer", "Error Count"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticSetting.LoopControlParameter",
          "CIM_DiagnosticSetting.OtherLoopControlDescription"} ]
   uint16 LoopControl[];

      [Write, Description (
          "Provides additional information for LoopControl when its "
          "value is set to 1 ('Other')."), 
       ModelCorrespondence { 
          "CIM_DiagnosticSetting.LoopControlParameter"} ]
   string OtherLoopControlDescriptions;

      [Write, Description (
          "The ResultPersistence property is a directive from a "
          "diagnostic client to a diagnostic provider.  It allows the "
          "client to specify to the diagnostic service provider how "
          "long to persist the messages that result from execution of "
          "a diagnostic service.  This applies to instances of "
          "DiagnosticResult as well as the preferred use of "
          "DiagnosticServiceRecord.  The timeout period starts upon "
          "completion of the diagnostic action described by the DiagnosticService.\n"
          "Here is a summary of the choices and behaviors for "
          "different ResultPersistence values:\n"
          "0 = \"No Persistence\":\n"
          "Setting the timer to zero tells the provider not to persist "
          "the diagnostic result.  The diagnostic information is only "
          "available while the diagnostic is executing or at its conclusion.\n"
          "Value > 0 and < 0xFFFFFFFF = \"Persist With TimeOut\":\n"
          "Setting the ResultPersistenceOption to a integer will cause "
          "the DiagnosticResult to be persisted for that number of "
          "seconds.  At the end of that time, the DiagnosticResult may "
          "be deleted by the diagnostic service provider.\n"
          "0xFFFFFFFF = \"Persist Forever\":\n"
          "By setting the timeout value to the very large value, "
          "0xFFFFFFFF, the provider shall persist results forever.  In "
          "this case, the client MUST bear the responsibility for "
          "deleting them."), 
       Units ("Seconds") ]
   uint32 ResultPersistence;

      [Experimental, Description (
          "This property, along with the locale information in "
          "LocalizationCapabilities and DiagnosticServiceRecord, meets "
          "the requirement to specify locale for results produced by a "
          "diagnostic service.  A locale indicates a particular "
          "geographical, political, or cultural region.  The Locales "
          "property of the DiagnosticSetting class is an array of "
          "strings whose entries specify a language to be used in the "
          "formulation of information requested by or delivered to a "
          "client as a result of running a diagnostic service.  It is "
          "specified by the client as an input parameter to the "
          "RunDiagnostic method, by virtue of its inclusion in this "
          "Setting class which is a parameter of the method.  A single "
          "Setting object may specify more than one Locale.  In this "
          "case, information MUST be returned in each language "
          "specified. \n\n"
          "Each array entry consists of three sub-strings, separated "
          "by underscores:\n"
          "- The first sub-string is the language code, as specified "
          "in ISO639.\n"
          "- The second sub-string is the country code, as specified "
          "in ISO3166.\n"
          "- The third sub-string is a variant, which is vendor specific.\n"
          "For example, US English appears as: \"en_US_WIN\", where "
          "the \"WIN\" variant would specify a Windows "
          "browser-specific collation (if one exists).  Since the "
          "variant is not standardized, it is not commonly used and "
          "generally is limited to easily recognizable values "
          "(\"WIN\", \"UNIX\", \"EURO\", etc.) used in standard "
          "environments.  The language and country codes are required; "
          "the variant may be empty."), 
       ModelCorrespondence 
          {"CIM_LocalizationCapabilities.SupportedOutputLocales"} ]
   string Locales[];

      [Experimental, Write, Description (
          "A client MAY want the ability to specify the depth of "
          "results returned when a diagnostic service is invoked.  A "
          "client MUST only select a TestResultLevel that is supported "
          "in the DiagnosticServiceCapabilities.  This property is "
          "used in conjunction with specifying the 'Results' value in "
          "LogOptions.  The ranges are from a simple pass/fail to "
          "large logs, diaries, etc.  The five levels of verbosity are "
          "defined as follows:\n"
          "* \"Minimum\" (value=2) is specified if the least verbose "
          "level of result information is desired; typically this is "
          "Pass or Fail.\n"
          "* \"Short\" (value=3) is the shortest form of standard messaging.\n"
          "* \"Standard\" (value=4) is standard messaging.\n"
          "* \"Long\" (value=5) is the longest form of standard messaging.\n"
          "* \"Full\" (value=6) is a request for all information "
          "available, regardless of size.\n"
          "The default, when no value is specified, is \"Standard\"."), 
       ValueMap {"2", "3", "4", "5", "6"}, 
       Values {"Minimum", "Short", "Standard", "Long", "Full"}, 
       ModelCorrespondence { 
          "CIM_DiagnosticServiceCapabilities.SupportedResultLevels",
          "CIM_DiagnosticSetting.LogOptions"} ]
   uint16 TestResultLevel;
};


// ==================================================================
// DiagnosticResult
// ==================================================================
   [Deprecated {"CIM_DiagnosticServiceRecord"}, Version ("2.7.1000"), 
    Description (
       "When a DiagnosticTest Service is running, test results are "
       "reported using a DiagnosticResult object, or one of its "
       "subclasses.  A DiagnosticTest may be running because its "
       "Service is Started or due to an invocation of the RunTest "
       "method.  Diagnostic Results are related to their Test via an "
       "instance of the DiagnosticResultsForMSE association.\n"
       "For every running of DiagnosticTest, a new instance of "
       "DiagnosticResult, or one of it's subclasses should be "
       "created.") ]
class CIM_DiagnosticResult {

      [Deprecated {"No Value"}, Key,
       Propagated ("CIM_DiagnosticTest.CreationClassName"), 
       Description (
          "The scoping Test's CreationClassName."), 
       MaxLen (256) ]
   string DiagnosticCreationClassName;

      [Deprecated {"No Value"}, Key,
       Propagated ("CIM_DiagnosticTest.Name"), Description (
          "The scoping Test's Name."), 
       MaxLen (256) ]
   string DiagnosticName;

      [Deprecated {"No Value"}, Key,
       Propagated ("CIM_DiagnosticTest.SystemCreationClassName"), 
       Description (
          "The scoping Test's SystemCreationClassName."), 
       MaxLen (256) ]
   string DiagSystemCreationClassName;

      [Deprecated {"No Value"}, Key,
       Propagated ("CIM_DiagnosticTest.SystemName"), Description (
          "The scoping Test's SystemName."), 
       MaxLen (256) ]
   string DiagSystemName;

      [Deprecated {"CIM_DiagnosticServiceRecord.ExecutionID"}, Key, 
       Description (
          "The Unique identifier for an instance of Diagnostic "
          "Results."), 
       MaxLen (1024) ]
   string ExecutionID ;

      [Deprecated {"CIM_LogRecord.MessageTimestamp"}, Description (
          "The date and time the result was last updated.") ]
   datetime TimeStamp;

      [Deprecated {"No Value"}, Description (
          "This property is being deprecated.  Tests should be grouped "
          "at the test level, not by the model.  /n If this property "
          "is TRUE, then this DiagnosticResult summarizes the results "
          "from the execution of a packaged set of DiagnosticTests.  "
          "The Tests in the package can be identified by following the "
          "DiagnosticResultForTest association to the test and then "
          "using the DiagnosticTest InPackage aggregation.  The "
          "individual Results can be broken out by instantiating "
          "DiagnosticResults for the individual lower level tests and "
          "aggregating into the 'summary' Result using the "
          "DiagnosticResultInPackage association.") ]
   boolean IsPackage;

      [Deprecated {"CIM_Job.StartTime"}, Description (
          "The date and time when this test started.") ]
   datetime TestStartTime;

      [Deprecated {"No Value"}, Description (
          "The date and time when this test completed.") ]
   datetime TestCompletionTime;

      [Deprecated {"No Value"}, Description (
          "Describes how the test is progressing.  For example, if the "
          "test was discontinued, the TestState will be \"Stopped\" "
          "(value=5), or if testing is currently executing, TestState "
          "will be \"In Progress\" (4)."), 
       ValueMap {"0", "1", "2", "3", "4", "5"}, 
       Values {"Unknown", "Other", "Passed", "Failed", "In Progress",
          "Stopped"}, 
       ModelCorrespondence { 
          "CIM_DiagnosticResult.OtherStateDescription"} ]
   uint16 TestState;

      [Deprecated {"No Value"}, Description (
          "When \"Other\" (value=1) is entered in the TestState "
          "property, OtherStateDescription can be used to describe the "
          "test's state."), 
       ModelCorrespondence {"CIM_DiagnosticResult.TestState"} ]
   string OtherStateDescription;

      [Deprecated {"No Value"}, Description (
          "Estimated number of seconds to perform the Diagnostic Test "
          "indicated by the DiagnosticCreationClassName and "
          "DiagnosticName properties.  After the test has completed, "
          "the actual elapsed time can be determined by subtracting "
          "the TestStartTime from the TestCompletionTime.  A similar "
          "property is defined in the association, DiagnosticTest "
          "ForMSE.  The difference between the two properties is that "
          "the value stored in the association is a generic test "
          "execution time for the Element and the Test.  But, the "
          "value here (in DiagnosticResult) is the estimated time that "
          "this instance with the given settings would take to run the "
          "test.  A CIM Consumer can compare this value with the value "
          "in the association DiagnosticTestForMSE to get an idea what "
          "impact their settings have on test execution."), 
       Units ("Seconds"), 
       ModelCorrespondence { 
          "CIM_DiagnosticTestForMSE.EstimatedTimeOfPerforming"} ]
   uint32 EstimatedTimeOfPerforming;

      [Deprecated {"CIM_LogRecord.RecordData"}, Description (
          "TestResults stores one or more textual results from the "
          "execution of the DiagnosticTest(s) referenced by the "
          "DiagnosticCreationClassName and DiagnosticName properties.  "
          "One entry is considered a cell location in the array.  Each "
          "entry is time stamped and contains the following "
          "information, in the following format:\n"
          " LogOption|yyymmddhhttssoutc|TestName|message_text\n"
          " Where:\n"
          "LogOption = string identical to the LogOption value in "
          "DiagnosticSetting that was used to enable logging this message.\n"
          "yyyy = year, e.g. 2000\n"
          "mm = month (01 - 12)\n"
          "dd = day (01 - 31)\n"
          "hh = hour (00 - 24)\n"
          "tt = minute (00-59)\n"
          "ss = second (00-59)\n"
          "o = \"+\" or \"-\" indicating the sign of the UTC "
          "correction field\n"
          "utc = offset from UTC (Universal Coordinated Time) in minutes\n"
          "TestName = Internal test name or current internal subtest "
          "name that sent the message.\n"
          "Textual message = free form string that is the 'test "
          "result'."), 
       ArrayType ("Ordered") ]
   string TestResults[];

      [Deprecated {"CIM_Job.PercentComplete"}, Description (
          "The percentage of the test that has executed thus far, if "
          "the TestState property is set to \"In Progress\" or the "
          "percentage of the complete test that was executed if the "
          "TestState property is set to any of the completed states "
          "(\"Passed\", \"Failed\" or \"Stopped\").  Final results may "
          "be based on less than 100% coverage due to the parameters "
          "defined in DiagnosticSetting (such as QuickMode, "
          "PercentOfTestCoverage or HaltOnError)."), 
       Units ("Percent"), MinValue (0), MaxValue (100) ]
   uint8 PercentComplete;
   // ---------  Properties below here are copied from  ------------------
   // ---------  DiagnosticSettings                     ------------------
   // Note that the DiagnosticSetting object can be modified at any time,
   // and the current test settings can be lost. When RunTest starts
   // execution the settings, which are time sensitive, should be evaluated
   // and captured.

      [Deprecated {"CIM_DiagnosticServiceRecord.TestWarningLevel"},
       Write, Description (
          "Sets the level of warning messages to be logged.  If for "
          "example no warning information is required, the level would "
          "be set to \"No Warnings\" (value=0).  Using \"Missing "
          "Resources\" (value=1) will cause warnings to be generated "
          "when required resources or hardware are not found.  Setting "
          "the value to 2, \"Testing Impacts\", results in both "
          "missing resources and 'test impact' warnings (for example, "
          "multiple retries required) to be reported."), 
       ValueMap {"0", "1", "2", "3"}, 
       Values {"No Warnings", "Missing Resources", "Testing Impacts",
          "All Warnings"} ]
   uint16 TestWarningLevel;

      [Deprecated {"CIM_DiagnosticSetting.LogOptions"}, Write, 
       Description (
          "When this flag is true, the diagnostic test will report "
          "'soft errors'.  In this context, a soft error is a message "
          "from the diagnostic reporting a known defect in the "
          "hardware or driver configuration, or execution "
          "environment.  Examples are: 'Not enough memory', 'Driver "
          "IOCTL not implemented', 'Video RAM compare failed during "
          "polygon fill test (A known defect in the video chipset)', "
          "etc.") ]
   boolean ReportSoftErrors;

      [Deprecated {"CIM_DiagnosticSetting.LogOptions"}, Write, 
       Description (
          "When this flag is true, the diagnostic test will report "
          "'status messages'.  In this context, a status message "
          "indicates that the diagnostic code is at a checkpoint.  "
          "Examples are: \"Completion of phase 1\", \"Complex "
          "pattern\", etc.") ]
   boolean ReportStatusMessages;

      [Deprecated {"CIM_DiagnosticServiceRecord.HaltOnError"}, Write, 
       Description (
          "When this flag is true, the test will halt after finding "
          "the first error.") ]
   boolean HaltOnError;

      [Deprecated {"CIM_DiagnosticServiceRecord.QuickMode"}, Write, 
       Description (
          "When this flag is true, the test software should attempt to "
          "run in an accelerated fashion either by reducing the "
          "coverage or number of tests performed.") ]
   boolean QuickMode;

      [Deprecated {"CIM_DiagnosticServiceRecord.PercentOfTestCoverage"},
       Write, Description (
          "Requests the diagnostic software to reduce test coverage to "
          "the specified percentage.  For example, a hard drive scan "
          "test could be asked to run at 50%.  The most effective way "
          "to accomplish this is for the test software to scan every "
          "other track, as opposed to only scanning the first half of "
          "a drive.  It is assumed that the effectiveness of the test "
          "is impacted proportional to the percentage of testing "
          "requested.  Permissible values for this property range from "
          "0 to 100.\n"
          "This property may not be applicable to all tests.  If it "
          "can be set for a test, the value 7 (\"Supports PercentOf "
          "TestCoverage\") should be entered into the DiagnosticTest's "
          "Characteristics array."), 
       Units ("Percent"), MinValue (0), MaxValue (100), 
       ModelCorrespondence 
          {"CIM_DiagnosticServiceCapabilities.SupportedServiceModes"} ]
   uint8 PercentOfTestCoverage;
};

// ==================================================================
// DiagnosticResultForMSE
// ==================================================================
   [Association, Deprecated {"No Value"}, Version ("2.7.1000"), 
    Description (
       "This class is being deprecated as part of the deprecation of "
       "the DiagnosticResult class.\n"
       "This is an association class relating diagnostic test results "
       "to the ManagedSystemElement that is/was tested.") ]
class CIM_DiagnosticResultForMSE {

      [Deprecated {"No Value"}, Key, Description (
          "The diagnostic result.") ]
   CIM_DiagnosticResult REF Result;

      [Deprecated {"No Value"}, Key, Description (
          "The ManagedSystemElement to which the diagnostic result "
          "applies.") ]
   CIM_ManagedSystemElement REF SystemElement;
};



// ==================================================================
// DiagnosticService
// ==================================================================
   [Experimental, Abstract, Version ("2.7.1000"), Description (
       "The CIM_DiagnosticService class provides the ability to start "
       "a service that functions to participate in a problem "
       "determination process.  Specific diagnostic services may be "
       "defined by subclassing this class.  Examples of a diagnostic "
       "service are tests, information retrievers, exercisers, and "
       "ports to external executives.") ]
class CIM_DiagnosticService : CIM_Service {

      [Description (
          "The RunDiagnostic method executes this test for the "
          "specified ManagedSystemElement (defined using the "
          "SystemElement input parameter).  The capabilities for the "
          "diagnostic service will indicate where the results from the "
          "test job are stored.  How the test should execute, i.e.  "
          "its settings, is defined in a DiagnosticSetting object (or "
          "by a subclass of DiagnosticSetting).  A reference to a "
          "Setting object is specified using the Setting input "
          "parameter.  If a reference is not passed into the method, "
          "then a default DiagnosticSetting may be used.\n"
          "When RunDiagnostic starts execution, the settings, which "
          "are time sensitive, should be evaluated and captured.  This "
          "is suggested since the DiagnosticSetting object can be "
          "modified at any time, and therefore the current test "
          "settings could be lost.\n"
          "If 0 is returned, the function completed successfully and "
          "no ConcreteJob instance is created.  If 0x1000 a "
          "ConcreteJob will be started."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "..", "0x1000", "..",
          "0x8000.."}, 
       Values {"Job completed with no error", "Not Supported",
          "Unknown", "Timeout", "Failed", "Invalid Parameter",
           "DMTF Reserved", "Method parameters checked - job started",
          "Method Reserved", "Vendor Specific"} ]
   uint32 RunDiagnostic(
       [IN,  Description ("Specifies the element upon which the "
       "DiagnosticService SHOULD be run.") ]
       CIM_ManagedElement REF ManagedElement,
       [IN, Description ("Specifies the desired settings that "
       "SHOULD be applied to the Diagnostic.  If null, then "
       "the Diagnostic's defaults MAY be used.") ]
       CIM_DiagnosticSetting REF DiagSetting,
       [IN, Description ("Specifies the desired settings that "
       "SHOULD be applied to the resulting Job.  If null and a "
       "resulting Job is required (i.e., the Diagnostic is long "
       "running), then the test's defaults MAY be used.") ]
       CIM_JobSettingData REF JobSetting,
       [IN(FALSE), OUT,
       Description ("Returns a handle to the resulting Job." ) ]
       CIM_ConcreteJob REF Job);
};


// ==================================================================
// DiagnosticTest
// ==================================================================
   [Version ("2.7.1000"), Description (
       "The CIM_DiagnosticTest class represents the framework for "
       "running diagnostic tests.  Specific diagnostic tests may be "
       "defined by subclassing and/or instantiating this object.  To "
       "provide more detail for a type of test(s) (i.e, additional "
       "properties and methods), subclassing is appropriate.  Note "
       "that a DiagnosticTest can be simultaneously executed against "
       "several elements.  If so, a DiagnosticTest may launch a "
       "ConcreteJob to represent each execution.") ]
class CIM_DiagnosticTest : CIM_DiagnosticService {

      [Description (
          "The descriptions for each Characteristic are below:\n"
          "\n"
          "* \"Is Exclusive\" (value=2) is specified for the test "
          "module only if the diagnostic cannot run more than one test "
          "at a time, regardless of how many SystemElements are "
          "supported.  Typically, this occurs when hardware or "
          "software constraints prevent the test from running as "
          "multiple, concurrent instances.  If the diagnostic can be "
          "run against multiple SystemElements, but only once per "
          "Element, then set the IsExclusiveForMSE boolean property on "
          "the appropriate instances of DiagnosticTestForMSE.\n"
          "\n"
          "* If \"Is Interactive\" (value=3) is set, then the "
          "diagnostic displays a message either before, during or "
          "after testing.\n"
          "\n"
          "* Set \"Is Destructive\" (value=4) if the diagnostic will "
          "destroy data, or reconfigure the Element that is being tested.\n"
          "\n"
          "* \"Is Risky\" (value=5) indicates that data loss may occur "
          "if the test is interrupted.  Some tests make copies of "
          "data, perform the test, and restore the data returning the "
          "tested entity to its previous configuration.  If the test "
          "is interrupted, then loss of data or reconfiguration of the "
          "tested ManagedSystemElement may occur.\n"
          "\n"
          "* If \"Is Package\" (value=6) is set, this test is actually "
          "a set of lower level diagnostics, that are packaged "
          "together by the test.  This packaging is implemented by the "
          "diagnostic test, not aggregated by CIM.  Information and "
          "results associated with the individual tests in the package "
          "may be requested by using the \"Subtests\" value in the "
          "DiagnosticSetting.LogOptions array.\n"
          "\n"
          "\"Supports PercentOfTestCoverage\" (value=7) indicates that "
          "a request for reduced test coverage can be specified using "
          "the PercentOfTestCoverage property of Diagnostic Setting.\n"
          "\n"
          "\"Is Synchronous\" (value=8) indicates that this diagnostic "
          "service will complete before the RunDiagnostic method "
          "returns to the caller.  Otherwise, RunDiagnostic may return "
          "a reference to CIM_Job object that can be used for "
          "monitoring and interacting with the diagnostic service.  If "
          "the service is synchronous, this capability is lost.  "
          "Additionally, in certain environments, the client may be "
          "\"blocked\" from further action until the service completes.\n"
          "Also, the values \"Unknown\" (0) and \"Other\" (1) may be "
          "specified.  If \"Other\" is defined, additional detail may "
          "be found in the OtherCharacteristicDescription property of "
          "this class."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6", "7", "8"}, 
       Values {"Unknown", "Other", "Is Exclusive", "Is Interactive",
          "Is Destructive", "Is Risky", "Is Package",
           "Supports PercentOfTestCoverage", "Is Synchronous"}, 
       ModelCorrespondence { 
          "CIM_DiagnosticTest.OtherCharacteristicDescription"} ]
   uint16 Characteristics[];

      [Description (
          "Provides additional information for the Characteristic when "
          "its value is set to 1 (\"Other\")."), 
       ModelCorrespondence {"CIM_DiagnosticTest.Characteristics"} ]
   string OtherCharacteristicDescription;

      [Deprecated {"CIM_DiagnosticTest.Started"}, Description (
          "Indicates if this test is currently being performed.  "
          "property is set to TRUE.  To determine which ManagedSystem "
          "Element is being tested, query the DiagnosticResult objects "
          "associated with this test (query DiagnosticResultForTest), "
          "and for which the TestState equals 4 (\"In Progress\").  "
          "The DiagnosticResult object is associated with the System "
          "Element under test, using DiagnosticResultForMSE.\n"
          "The use of this property has been deprecated.  Instead, the "
          "inherited property Started should be used.") ]
   boolean IsInUse;

      [Deprecated {"CIM_ServiceAffectsElement.AffectedElement"}, 
       Description (
          "The \"Expensive\" qualifier can be applied to this class "
          "and its RunTest method.  If so, the ResourcesUsed property "
          "describes the resources that are capitalized, based on a "
          "default setup for the test.  Multiple resources can be "
          "specified since the property is an array.\n"
          "The use of this property has been deprecated.  Instead, "
          "association, ServiceAffectsElement, should be between the "
          "DiagnosticTest and the Resource being used."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6", "7", "8", "9",
          "10", "11", "12", "13", "14", "15", "16", "17", "18", "19",
          "20", "21", "22", "23", "24", "25", "26"}, 
       Values {"CPU", "Memory", "Hard Disk", "CDROM", "Floppy",
           "PCI Bus", "USB Bus", "1394 Bus", "SCSI Bus", "IDE Bus",
          "Network", "ISA Bus", "EISA Bus", "VESA Bus", "PCMCIA Bus",
          "CardBus", "Access.bus", "NuBus", "AGP", "VME Bus",
           "Sbus IEEE 1396-1993", "MCA Bus", "GIO Bus", "XIO Bus",
           "HIO Bus", "PMC Bus", "SIO Bus"} ]
   uint16 ResourcesUsed[];

      [Deprecated {"CIM_DiagnosticService.RunDiagnostic"}, 
       Description (
          "The RunTest method executes this test for the specified "
          "specified ManagedSystemElement (defined using the "
          "SystemElement input parameter).\n"
          "The use of this method has been deprecated.  Instead, the "
          "RunDiagnostic method (inherited from DiagnosticService) "
          "should be used.\n"
          "Results of the test are stored in a DiagnosticResult "
          "object, a reference to which is returned as the Result "
          "output parameter.  How the test should execute, i.e.  its "
          "settings, is defined in a DiagnosticSetting object (or by a "
          "subclass of DiagnosticSetting).  A reference to a Setting "
          "object is specified using the Setting input parameter.  If "
          "a reference is not passed into the method, then a default "
          "DiagnosticSetting may be used.  This default Setting is "
          "associated with the DiagnoticTest using the DefaultSetting "
          "relationship of the Core Model.\n"
          "When RunTest starts execution, the settings, which are time "
          "sensitive, should be evaluated and captured.  This is "
          "suggested since the DiagnosticSetting object can be "
          "modified at any time, and therefore the current test "
          "settings could be lost.\n"
          "The method's return codes are expected to adhere to the XML "
          "return codes as they are introduced.  Currently, the "
          "standard return values are:\n"
          "0 = OK (function succeeded, but the test itself may have failed\n"
          "1 = Unspecified Error (function failed for unspecified reasons)\n"
          "2 = Not Implemented (function is not implemented for this instance)\n"
          "3 = Out Of Resources (component could not allocate required "
          "resources, e.g.  memory, disk space, etc.)\n"
          "In a subclass, the set of possible return codes could be "
          "specified, using a ValueMap qualifier on the method.  The "
          "strings to which the ValueMap contents are 'translated' may "
          "also be specified in the subclass as a Values array "
          "qualifier.") ]
   uint32 RunTest(
       [IN] CIM_ManagedSystemElement REF SystemElement,
       [IN] CIM_DiagnosticSetting REF Setting,
       [IN (false), OUT] CIM_DiagnosticResult REF Result);

      [Description (
          "Execution of this method will delete all instances of the "
          "DiagnosticResultForMSE object, for this DiagnosticTest and "
          "the specified ManagedSystemElement (defined using the "
          "SystemElement input parameter).  The DiagnosticResults "
          "referenced in the DiagnosticResultForMSE instances will be "
          "deleted.  Also the association DiagnosticResultForTest that "
          "refers to the DiagnosticResult object, and this test will "
          "be deleted.\n"
          "One output parameter is defined - ResultsNotCleared - which "
          "is a string array that lists the keys of the "
          "DiagnosticResults which could not be deleted.  This "
          "information enables those Results to be revisited and "
          "either manually removed, or other corrective action taken.\n"
          "The method's return codes are expected to adhere to the XML "
          "return codes as they are introduced.  Currently, the "
          "standard return values are:\n"
          "0 = OK (function succeeded, but the test itself may have failed)\n"
          "1 = Unspecified Error (function failed for unspecified reasons)\n"
          "2 = Not Implemented (function is not implemented for this instance)\n"
          "3 = Out Of Resources (component could not allocate required "
          "resources, e.g.  memory, disk space, etc.)\n"
          "In a subclass, the set of possible return codes could be "
          "specified, using a ValueMap qualifier on the method.  The "
          "strings to which the ValueMap contents are 'translated' may "
          "also be specified in the subclass as a Values array "
          "qualifier.") ]
   uint32 ClearResults(
       [IN] CIM_ManagedSystemElement REF SystemElement,
       [IN (false), OUT] string ResultsNotCleared[]);

      [Deprecated {"CIM_EnabledLogicalElement.RequestedState"}, 
       Description (
          "After invocation of this method and its completion, the "
          "specified test(s) will be discontinued for the indicated "
          "ManagedSystemElement (defined by the SystemElement input parameter).\n"
          "The use of this method has been deprecated.  Instead the "
          "RequestedState (inherited property from "
          "EnabledLogicalElement) should be used to control the "
          "execution of the test.\n"
          "The test to discontinue is specified using the Result input "
          "parameter.  If all instances of this test should be stopped "
          "for the SystemElement, then the Result reference should be "
          "NULL.  Upon completion of the method, test status and other "
          "information (such as PercentComplete) will be stored in the "
          "DiagnosticResult instance defined by the Result input "
          "parameter.  The output parameter, TestingStopped, is used "
          "as follows:\n"
          "Set to TRUE if testing was successfully stopped.\n"
          "Set to FALSE if the current test(s) can not be stopped.\n"
          "If set to FALSE, testing will stop when the diagnostic is "
          "able to do so safely.  To determine if/when the testing is "
          "stopped, check the TestState property in the "
          "DiagnosticResult instance defined by the Result parameter.  "
          "TestState will change from \"In Progress\" to \"Stopped\" "
          "(from 4 to 5).\n"
          "The method's return codes are expected to adhere to the XML "
          "return codes as they are introduced.  Currently, the "
          "standard return values are:\n"
          "0 = OK (function succeeded, but the test itself may have failed\n"
          "1 = Unspecified Error (function failed for unspecified reasons)\n"
          "2 = Not Implemented (function is not implemented for this instance)\n"
          "3 = Out Of Resources (component could not allocate required "
          "resources, e.g.  memory, disk space, etc.)\n"
          "In a subclass, the set of possible return codes could be "
          "specified, using a ValueMap qualifier on the method.  The "
          "strings to which the ValueMap contents are 'translated' may "
          "also be specified in the subclass as a Values array "
          "qualifier.") ]
   uint32 DiscontinueTest(
       [IN] CIM_ManagedSystemElement REF SystemElement,
       [IN] CIM_DiagnosticResult REF Result,
       [IN (false), OUT] Boolean TestingStopped);
};

// ==================================================================
// DiagnosticResultForTest
// ==================================================================
   [Association, Deprecated {"No Value"}, Version ("2.7.1000"), 
    Description (
       "This class is being deprecated as part of the deprecation of "
       "the DiagnosticResult class.\n"
       "This is an association class to relate the results of a test "
       "to the test itself.") ]
class CIM_DiagnosticResultForTest {

      [Deprecated {"No Value"}, Key, Weak, Min (1), Max (1), 
       Description (
          "The result object.") ]
   CIM_DiagnosticResult REF DiagnosticResult;

      [Deprecated {"No Value"}, Key, Min (1), Max (1), Description (
          "The test that generated the result object.") ]
   CIM_DiagnosticTest REF DiagnosticTest;
};

// ==================================================================
// DiagnosticTestForMSE
// ==================================================================
   [Association, Deprecated {"CIM_AvailableDiagnosticService"},
    Version ("2.7.1000"), Description (
       "This class is being deprecated to promote its usage to the "
       "DiagnosticService level.\n"
       "This is an association class that relates a DiagnosticTest to "
       "a ManagedSystemElement.  Consumers wishing to 'diagnose' a "
       "particular Element could query this association, for the "
       "Element, to determine what tests are available.") ]
class CIM_DiagnosticTestForMSE : CIM_ProvidesServiceToElement {

      [Deprecated {"CIM_AvailableDiagnosticService.ServiceProvided"},
       Override ("Antecedent"), Description (
          "The test that may be run against a ManagedSystemElement.") ]
   CIM_DiagnosticTest REF Antecedent;

      [Deprecated {"CIM_AvailableDiagnosticService.UserOfService"},
       Override ("Dependent"), Description (
          "The ManagedSystemElement that can be tested.") ]
   CIM_ManagedSystemElement REF Dependent;

      [Deprecated 
          {"CIM_AvailableDiagnosticService.EstimatedTimeOfPerforming"}, 
       Description (
          "Estimated number of seconds to perform the referenced "
          "DiagnosticTest against the ManagedSystemElement.  Since "
          "execution times could vary by Element, this property is "
          "located in the association between the two entities.  It is "
          "also captured in DiagnosticResult, in the "
          "EstimatedTimeOfPerforming property.\n"
          "A CIM Consumer can compare this value with the value in "
          "DiagnosticResult to get an idea of what impact their "
          "settings have on test execution."), 
       Units ("Seconds"), 
       ModelCorrespondence { 
          "CIM_DiagnosticResult.EstimatedTimeOfPerforming"} ]
   uint32 EstimatedTimeOfPerforming;

      [Deprecated {"CIM_ServiceAffectsElement.ElementEffects"}, 
       Description (
          "This property is being deprecated since the same "
          "characterisitic can be published in the "
          "CIM_ServiceAffectsElement.ElementEffects array as \"Value = "
          "2, \"Exclusive Use\".\n"
          "If the DiagnosticTest referenced in this object can be run "
          "concurrently against multiple SystemElements, but only run "
          "one at a time for the referenced ManagedSystemElement, then "
          "this boolean is set to TRUE.  Alternately, if the test can "
          "NOT be run concurrently irregardless of the System Elements "
          "being tested, then the more general \"Is Exclusive\" "
          "enumerated value (2) should be set in DiagnosticTest.  "
          "Characteristics.") ]
   boolean IsExclusiveForMSE;
};


// ==================================================================
// DiagnosticSettingForTest
// ==================================================================
   [Association, Deprecated {"CIM_ElementSetting"},
    Version ("2.7.1000"), Description (
       "This class is no longer required and is being deprecated.  Use "
       "ElementSetting (its parent) instead if the association is needed.\n"
       "This is an association class to relate test settings with "
       "diagnostic tests.") ]
class CIM_DiagnosticSettingForTest : CIM_ElementSetting {

      [Deprecated {"CIM_ElementSetting.Element"}, Override ("Element"), 
       Description (
          "The Test that can use the Setting object.") ]
   CIM_DiagnosticTest REF Element;

      [Deprecated {"CIM_ElementSetting.Setting"}, Override ("Setting"), 
       Description (
          "The Setting that can be applied to the execution of the "
          "DiagnosticTest.") ]
   CIM_DiagnosticSetting REF Setting;
};


// ==================================================================
// DiagnosticTestInPackage
// ==================================================================
   [Association, Deprecated {"No value"}, Aggregation,
    Version ("2.7.0"), Description (
       "This class is being deprecated.  Tests should be grouped at "
       "the test level, not in the model.  Therefore, the association "
       "is not appropriate.  /n This is an association class that "
       "identifies a Diagnostic Test as made up of lower level Tests.  "
       "In this case, the test identified as the GroupComponent "
       "reference (i.e, the higher level test) would have the \"Is "
       "Package\" enumerated value specified in DiagnosticTest.  "
       "Characteristics.") ]
class CIM_DiagnosticTestInPackage : CIM_Component {

      [Deprecated {"No value"}, Aggregate, Override ("GroupComponent"), 
       Description (
          "The DiagnosticTest object that acts as the container for "
          "all the tests of the package.") ]
   CIM_DiagnosticTest REF GroupComponent;

      [Deprecated {"No value"}, Override ("PartComponent"), 
       Description (
          "The DiagnosticTest object that is one of the elements of "
          "the package.") ]
   CIM_DiagnosticTest REF PartComponent;
};


// ==================================================================
// DiagnosticResultInPackage
// ==================================================================
   [Association, Deprecated {"No value"}, Aggregation,
    Version ("2.7.0"), Description (
       "This class is being deprecated.  Tests should be grouped at "
       "the test level, not by the model.  Therefore, this association "
       "is no longer appropriate.  /n This is an association class "
       "that identifies a Diagnostic Result as made up of lower level "
       "Results.  In this case, the Result identified as the "
       "PackageResult reference (i.e., the higher level result) would "
       "have its IsPackage property set to TRUE.") ]
class CIM_DiagnosticResultInPackage {

      [Deprecated {"No value"}, Key, Aggregate, Description (
          "The DiagnosticResult object that acts as the container for "
          "all the results of the package.") ]
   CIM_DiagnosticResult REF PackageResult;

      [Deprecated {"No value"}, Key, Description (
          "The DiagnosticResult object that is one of the elements of "
          "the package.") ]
   CIM_DiagnosticResult REF Result;
};


// ==================================================================
// DiagnosticServiceCapabilities
// ==================================================================
   [Experimental, Version ("2.7.1000"), Description (
       "DiagnosticServiceCapabilities is a class that describes the "
       "capabilities of the diagnostic service.  This provides the "
       "means for the diagnostic service to describe its abilities, "
       "limitations, and/or potential for use of various diagnostic "
       "service parameters.  For example, what types of settings the "
       "diagnostic service supports.") ]
class CIM_DiagnosticServiceCapabilities : CIM_Capabilities {

      [Description (
          "The SupportedServiceModes property lists the operational "
          "modes that are supported by the Diagnostic Service./n These "
          "modes may correspond to, but are not limited to, settings "
          "that may be applied to a Diagnostic Service."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6"}, 
       Values {"Unknown", "Other", "TestWarningLevel",
          "PercentOfTestCoverage", "QuickMode", "HaltOnError",
          "ResultPersistence"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { "CIM_DiagnosticServiceCapabilities." 
          "OtherSupportedServiceModesDescriptions"} ]
   uint16 SupportedServiceModes[];

      [Description (
          "Provides additional information for SupportedServiceMode "
          "when its value is set to 1 (\"Other\")."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence { "CIM_DiagnosticServiceCapabilities." 
          "SupportedServiceModes"} ]
   string OtherSupportedServiceModesDescriptions[];

      [Description (
          "The SupportedLoopControl property lists the loop controls "
          "that are supported by the Diagnostic Service."), 
       ValueMap {"0", "1", "2", "3", "4", "5"}, 
       Values {"Unknown", "Other", "Continuous", "Count", "Timer",
          "ErrorCount"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence {"CIM_DiagnosticSetting.LoopControl",
          "CIM_DiagnosticServiceCapabilities." 
          "OtherSupportedLoopControlDescriptions" } ]
   uint16 SupportedLoopControl[];

      [Description (
          "Provides additional information for SupportedLoopControl "
          "when its value is set to 1 (\"Other\")."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticServiceCapabilities.SupportedLoopControl"} ]
   string OtherSupportedLoopControlDescriptions[];

      [Description (
          "The SupportedLogOptions property lists the log options that "
          "are supported by the Diagnostic Service.  A brief summary "
          "of the various log options can be found in "
          "CIM_DiagnosticSetting.LogOptions."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6", "7", "8", "9",
          "10", "11", "12", "13", "14", "15" }, 
       Values {"Unknown", "Other", "Test Errors", "Soft Errors",
          "Status", "Warnings", "Hardware Configuration", "Debug",
          "Statistics", "Actions", "Software Configuration",
          "Subtests", "References", "Results", "Results Summary",
          "Setting Data"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticServiceCapabilities.OtherSupportedLogOptionDescriptions"} ]
   uint16 SupportedLogOptions[];

      [Description (
          "Provides additional information for SupportedLogOptions "
          "when its value is set to 1 (\"Other\")."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticServiceCapabilities.SupportedLogOptions"} ]
   string OtherSupportedLogOptionDescriptions[];

      [Description (
          "The SupportedLogStorage property lists the storage options "
          "for logging that are supported by the Diagnostic Service.\n"
          "The values are:\n"
          "\"ResultArray\" (Value = 2): Supports writing log "
          "information to the TestResult array of a DiagnosticResult instance.\n"
          "\"LogRecords\" (Value = 3): Supports writing log "
          "information to a vendor defined subclass of the "
          "DiagnosticServiceRecord class as recommended in the "
          "description of its parent class CIM_LogRecord.\n"
          "\"MessageLog\" (Value = 4): Supports writing log "
          "information using the defined methods of the MessageLog class.\n"
          "\"File\" (Value = 5): Supports writing log information to a "
          "file."), 
       ValueMap {"0", "1", "2", "3", "4", "5"}, 
       Values {"Unknown", "Other", "ResultArray", "LogRecords",
          "MessageLog", "File"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { "CIM_DiagnosticServiceCapabilities." 
          "OtherSupportedLogStorageDescriptions"} ]
   uint16 SupportedLogStorage[];

      [Description (
          "Provides additional information for SupportedLogStorage "
          "when its value is set to 1 (\"Other\")."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticServiceCapabilities.SupportedLogStorage"} ]
   string OtherSupportedLogStorageDescriptions[];

      [Description (
          "The SupportedExecutionControls property lists the job "
          "controls that are supported by the Diagnostic Service.  The "
          "values are:\n"
          "\"JobCreation\" (Value = 2): publishes that a ConcreteJob "
          "instance will be created to control the diagnostic job "
          "launched by the diagnostic service.\n"
          "\"KillJob\" (Value = 3): publishes that the diagnostic "
          "service has implemented the KillJob method in ConcreteJob.\n"
          "\"Enable/Disable Job\" (Value = 4): publishes that the "
          "diagnostic service can pause and resume execution of the "
          "diagnostic job.  This is accomplished by setting the "
          "RequestedState property that ConcreteJob inherits from "
          "CIM_EnabledLogicalElement to values Disabled to suspend and "
          "Enabled to resume.\n"
          "\"Shutdown Job\" (Value = 5): publishes that the diagnostic "
          "service can gracefully shutdown execution of the diagnostic "
          "job.  Which is accomplished by setting the RequestedState "
          "property that ConcreteJob inherits from "
          "CIM_EnabledLogicalElement to the value, Shut Down."), 
       ValueMap {"0", "1", "2", "3", "4", "5"}, 
       Values {"Unknown", "Other", "Job Creation", "Kill Job",
          "Enable/Disable Job", "Shutdown Job"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { "CIM_DiagnosticServiceCapabilities." 
          "OtherSupportedExecutionControlsDescriptions"} ]
   uint16 SupportedExecutionControls[];

      [Description (
          "Provides additional information for "
          "SupportedExecutionControls when its value is set to 1 "
          "(\"Other\")."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence { "CIM_ " 
          "DiagnosticServiceCapabilities.SupportedExecutionControls"} ]
   string OtherSupportedExecutionControlsDescriptions[];

      [Description (
          "The SupportedResultLevels property lists the verbosity "
          "levels that are supported by the Diagnostic Service.\n"
          "A client may want the ability to specify the depth of "
          "information returned when a diagnostic service is invoked.  "
          "This requirement ranges from a simple pass/fail to a need "
          "for large logs, diaries, etc.  The five levels of verbosity "
          "are defined as follows:\n"
          "* \"Minimum\" (value=2) is specified if the least verbose "
          "level of result information is desired; typically this is "
          "Pass or Fail.\n"
          "* \"Short\" (value=3) is the shortest form of standard messaging.\n"
          "* \"Standard\" (value=4) is standard messaging.\n"
          "* \"Long\" (value=5) is the longest form of standard messaging.\n"
          "* \"Full\" (value=6) is a request for all information "
          "available, regardless of size.\n"
          "The default, when no value is specified, is \"Standard\"."), 
       ValueMap {"2", "3", "4", "5", "6"}, 
       Values {"Minimum", "Short", "Standard", "Long", "Full"} ]
   uint16 SupportedResultLevels[];

      [Description (
          "Lists the level of warning messages that MAY be logged.  If "
          "for example no warning information is required, the level "
          "would be set to \"No Warnings\" (value=0).  Using \"Missing "
          "Resources\" (value=1) will cause warnings to be generated "
          "when required resources or hardware are not found.  Setting "
          "the value to 2, \"Testing Impacts\", results in both "
          "missing resources and 'test impact' warnings (for example, "
          "multiple retries required) to be reported."), 
       ValueMap {"0", "1", "2", "3"}, 
       Values {"No Warnings", "Missing Resources", "Testing Impacts",
          "All Warnings"} ]
   uint16 SupportedTestWarnings[];
};

// ==================================================================
// DiagnosticRecord
// ==================================================================
   [Experimental, Version ("2.7.1000"), Description (
       "Data related to Diagnostics may be recorded in various "
       "DiagnosticRecord objects.  The type of information that is "
       "recorded in a log is specified via the LogOptions property in "
       "DiagnosticSetting.") ]
class CIM_DiagnosticRecord : CIM_LogRecord {

      [Required, Description (
          "This property should reflect the value of the underlying "
          "DiagnosticService.Name property."), 
       ModelCorrespondence {"CIM_DiagnosticService.Name"} ]
   string ServiceName;

      [Required, Description (
          "A unique identifier representing a single execution of a "
          "DiagnosticService on an instance of a managed element.  All "
          "records created by this Service execution must have the "
          "same ExecutionID value, and that value must be unique "
          "across all Service executions.\n"
          "The ExecutionID property is distinct from "
          "LogRecord.RecordID in that a MessageLog may aggregate "
          "multiple records with the same ExecutionID, corresponding "
          "to a single invokation of a Service, but each of these "
          "records will have unique RecordIDs."), 
       ModelCorrespondence {"CIM_DiagnosticJob.ExecutionID"} ]
   string ExecutionID ;

      [Required, Description (
          "The date and time that the record instance should be "
          "deleted.  The expiration datetime should be set when the "
          "record is fully populated with record data.  The value "
          "should be calculated using the ResultPersistence property "
          "of the DiagnosticSetting class.\n"
          "If a ResultPersistence value is not provided, the "
          "ExpirationDate should be set to the current datetime.\n"
          "Once the date has expired, instances should be deleted as "
          "soon as possible."), 
       ModelCorrespondence {"CIM_DiagnosticSetting.ResultPersistence"} ]
   datetime ExpirationDate;

      [Description (
          "The RecordType property specifies the nature of the data "
          "being entered into the ServiceRecord.  The value in this "
          "property should match one of the values indicated by the "
          "DiagnosticSetting.LogOptions property.  A brief summary of "
          "the various log options can be found in "
          "CIM_DiagnosticSetting.LogOptions."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6", "7", "8", "9",
          "10", "11", "12", "13", "14", "15"}, 
       Values {"Unknown", "Other", "Test Errors", "Soft Errors",
          "Status", "Warnings", "Hardware Configuration", "Debug",
          "Statistics", "Actions", "Software Configuration",
          "Subtests", "References", "Results", "Result Summary",
          "Setting Data"}, 
       ModelCorrespondence {"CIM_DiagnosticSetting.LogOptions",
          "CIM_DiagnosticRecord.OtherRecordTypeDescription"} ]
   uint16 RecordType;

      [Description (
          "When \"Other\" (value=1) is entered in the RecordType "
          "property, OtherRecordTypeDescription can be used to "
          "describe the message type."), 
       ModelCorrespondence { 
          "CIM_DiagnosticSetting.OtherLogOptionsDescription",
          "CIM_DiagnosticRecord.RecordType"} ]
   string OtherRecordTypeDescription;

      [Description (
          "A locale indicates a particular geographical, political, or "
          "cultural region.  The Locale specifies the language used in "
          "creating the LogRecord data.  If the Locale property is "
          "empty, it is assumed that the default locale is en_US (English).\n"
          "The locale string consists of three sub-strings, separated "
          "by underscores:\n"
          "- The first sub-string is the language code, as specified "
          "in ISO639.\n"
          "- The second sub-string is the country code, as specified "
          "in ISO3166.\n"
          "- The third sub-string is a variant, which is vendor specific.\n"
          "For example, US English appears as: \"en_US_WIN\", where "
          "the \"WIN\" variant would specify a Windows "
          "browser-specific collation (if one exists).  Since the "
          "variant is not standardized, it is not commonly used and "
          "generally is limited to easily recognizable values "
          "(\"WIN\", \"UNIX\", \"EURO\", etc.) used in standard "
          "environments.  The language and country codes are required; "
          "the variant may be empty."), 
       ModelCorrespondence {"CIM_DiagnosticSetting.Locales"} ]
   string Locale;
};

// ==================================================================
// DiagnosticServiceRecord
// ==================================================================
   [Experimental, Version ("2.7.1000"), Description (
       "While a DiagnosticService is running, data generated by the "
       "service may be recorded in DiagnosticServiceRecord objects.  A "
       "DiagnosticServiceRecord is related to its MessageLog via an "
       "instance of the RecordInLog aggregation class.") ]
class CIM_DiagnosticServiceRecord : CIM_DiagnosticRecord {

      [Description (
          "If applicable, this string should contain one or more "
          "vendor specific error codes that the diagnostic service "
          "detected.  These error codes may be used by the vendor for "
          "variety of purposes such as: fault data base indexing, "
          "field service trouble ticketing, product quality tracking, "
          "part failure history, etc.  Since these codes are for "
          "vendor purposes they may assume any form.  Details on "
          "suggested use cases will be left to white papers.  The "
          "array of error codes has model correspondence with an "
          "ErrorCount array so the number of errors reported can be "
          "analyzed by individual error code."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence {"CIM_DiagnosticServiceRecord.ErrorCount"} ]
   string ErrorCode[];

      [Description (
          "Since some tests may detect transient and correctable "
          "errors such as a network diagnostic or memory test, an "
          "error count is useful to indicate the severity of the "
          "failure.  This field contains an integer value of the "
          "number of errors detected by the test.  The ErrorCount is "
          "an array with model correspondence to ErrorCode so that the "
          "test can report an ErrorCount on each type of error "
          "encountered.  It is recommended that hard errors and "
          "correctable or recoverable errors be given different codes "
          "so that clients with knowledge of the error codes can "
          "evaluate correctable, recoverable, and hard errors "
          "independently."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence {"CIM_DiagnosticServiceRecord.ErrorCode"} ]
   uint32 ErrorCount[];

      [Description (
          "Since some tests may be looped, it is useful to report how "
          "many iterations passed and failed.  This is relevant in "
          "analyzing transitory failures.  For example, if all the "
          "errors occurred in just one of 100 iterations, the device "
          "may be viewed as OK or marginal, to be monitored further "
          "rather then failed.  Note: LoopsPassed & LoopsFailed should "
          "add up to the loops completed.\n"
          "A value for this property would likely be reported with a "
          "DiagnosticServiceRecord.RecordType value = "
          "\"ResultSummary\", which contains a summary result covering "
          "all iterations of a looped service.") ]
   uint32 LoopsFailed;

      [Description (
          "Since some tests may be looped, it is useful to report how "
          "many iterations passed and failed.  This is relevant in "
          "analyzing transitory failures.  For example if all the "
          "errors occurred in in just one of 100 iterations, the "
          "device may be viewed as OK or marginal, to be monitored "
          "further rather then failed.  Note: LoopsPassed & "
          "LoopsFailed should add up to the loops completed.\n"
          "A value for this property would likely be reported with a "
          "DiagnosticServiceRecord.RecordType value = "
          "\"ResultSummary\", which contains a summary result covering "
          "all iterations of a looped service.") ]
   uint32 LoopsPassed;
};

// ==================================================================
// DiagnosticSettingRecord
// ==================================================================
   [Experimental, Version ("2.7.1000"), Description (
       "The DiagnosticSettingData that was used to when a Diagnostic "
       "was run.") ]
class CIM_DiagnosticSettingRecord : CIM_DiagnosticRecord {

      [Description (
          "The LogOptions property lists the log options that were "
          "requested for the Diagnostic Service.  A brief summary of "
          "the various log options can be found in "
          "CIM_DiagnosticSetting.LogOptions."), 
       ValueMap {"0", "1", "2", "3", "4", "5", "6", "7", "8", "9",
          "10", "11", "12", "13", "14", "15" }, 
       Values {"Unknown", "Other", "Test Errors", "Soft Errors",
          "Status", "Warnings", "Hardware Configuration", "Debug",
          "Statistics", "Actions", "Software Configuration",
          "Subtests", "References", "Results", "Results Summary",
          "Setting Data"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticSettingRecord.OtherLogOptionDescriptions",
          "CIM_DiagnosticSetting.LogOptions"} ]
   uint16 LogOptions[];

      [Description (
          "Provides additional information regarding the types of test "
          "messages that are logged when the property LogOptions "
          "includes the value 1 (\"Other\")."), 
       ModelCorrespondence {"CIM_DiagnosticSettingRecord.LogOptions",
          "CIM_DiagnosticSetting.OtherLogOptionsDescriptions"} ]
   string OtherLogOptionsDescriptions[];

      [Description (
          "When this flag is true, the test will halt after finding "
          "the first error.") ]
   boolean HaltOnError;

      [Description (
          "When this flag is true, the test software should attempt to "
          "run in an accelerated fashion either by reducing the "
          "coverage or number of tests performed.") ]
   boolean QuickMode;

      [Description (
          "The requested percentage of coverage for the diagnostic "
          "service.  For example, a hard drive scan test could be "
          "asked to run at 50%.  Permissible values for this property "
          "range from 0 to 100."), 
       Units ("Percent"), MinValue (0), MaxValue (100), 
       ModelCorrespondence 
          {"CIM_DiagnosticSetting.PercentOfTestCoverage"} ]
   uint8 PercentOfTestCoverage;

      [Description (
          "Array entries contain parameters corresponding to entries "
          "in the LoopControl array, limiting the number of times a "
          "test should be repeated with a single invocation of RunTest "
          "by a CIM client."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence {"CIM_DiagnosticSettingRecord.LoopControl",
          "CIM_DiagnosticSetting.LoopControlParameter"} ]
   string LoopControlParameter[];

      [Description (
          "LoopControl, used in conjunction with LoopControlParameter, "
          "sets one or more loop control mechanisms that limits the "
          "number of times a test should be repeated with a single "
          "invocation of RunTest by a CIM client.  There is an "
          "array-positional correspondence between LoopControl entries "
          "& LoopControlParameter entries.  The entries in these "
          "coupled arrays of loop controls can be used in a logical OR "
          "fashion to achieve the desired loop control.  For example, "
          "if a client wants to loop a test 1000 times, but quit if a "
          "timer runs out, it could set both controls into the "
          "LoopControl array as two separate entries in each array.  "
          "The looping test will terminate when the first of the two "
          "ORed conditions are met.\n"
          "A brief descriptions for each loop controls can be found in "
          "the description of DiagnosticSetting.LoopControl."), 
       ValueMap {"0", "1", "2", "3", "4", "5"}, 
       Values {"Unknown/Default", "Other", "Continuous", "Count",
          "Timer", "Error Count"}, 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticSetting.LoopControlParameter",
          "CIM_DiagnosticSettingRecord.OtherLoopControlDescription"} ]
   uint16 LoopControl[];

      [Description (
          "Provides additional information for LoopControl when its "
          "value is set to 1 ('Other')."), 
       ArrayType ("Indexed"), 
       ModelCorrespondence { 
          "CIM_DiagnosticSetting.OtherLoopControlParameter",
          "CIM_DiagnosticSettingRecord.LoopControl" } ]
   string OtherLoopControlDescriptions[];

      [Description (
          "The desired length of time to persist the messages that "
          "result from execution of a diagnostic service.  Here is a "
          "summary of the choices and behaviors for different "
          "ResultPersistence values:\n"
          "0 = \"No Persistence\":\n"
          "Setting the timer to zero tells the provider not to persist "
          "the diagnostic result.  The diagnostic information is only "
          "available while the diagnostic is executing or at its conclusion.\n"
          "Value > 0 and < 0xFFFFFFFF = \"Persist With TimeOut\":\n"
          "Setting the ResultPersistenceOption to a integer will cause "
          "the DiagnosticResult to be persisted for that number of "
          "seconds.  At the end of that time, the DiagnosticResult may "
          "be deleted by the diagnostic service provider.\n"
          "0xFFFFFFFF = \"Persist Forever\":\n"
          "By setting the timeout value to the very large value, "
          "0xFFFFFFFF, the provider shall persist results forever.  In "
          "this case, the client MUST bear the responsibility for "
          "deleting them."), 
       Units ("Seconds"), 
       ModelCorrespondence {"CIM_DiagnosticSetting.ResultPersistence"} ]
   uint32 ResultPersistence;

      [Description (
          "The desired depth of information that SHOULD be returned "
          "when a diagnostic service is invoked.  This property is "
          "used in conjunction with specifying the 'Results' value in "
          "LogOptions.  This requirement ranges from a simple "
          "pass/fail to a need for large logs, diaries, etc.  Five "
          "levels of verbosity are defined as follows:\n"
          "* \"Minimum\" (value=2) is specified if the least verbose "
          "level of result information is desired; typically this is "
          "Pass or Fail.\n"
          "* \"Short\" (value=3) is the shortest form of standard messaging.\n"
          "* \"Standard\" (value=4) is standard messaging.\n"
          "* \"Long\" (value=5) is the longest form of standard messaging.\n"
          "* \"Full\" (value=6) is a request for all information "
          "available, regardless of size.\n"
          "The default, when no value is specified, is \"Standard\"."), 
       ValueMap {"2", "3", "4", "5", "6"}, 
       Values {"Minimum", "Short", "Standard", "Long", "Full"}, 
       ModelCorrespondence { "CIM_DiagnosticSettings.TestResultLevel",
          "CIM_DiagnosticSettingRecord.LogOptions"} ]
   uint16 TestResultLevel;

      [Description (
          "The level of warning messages to be logged.  This property "
          "is used in conjunction with specifying the 'Warnings' value "
          "in LogOptions.  If for example no warning information is "
          "required, the level would be set to \"No Warnings\" "
          "(value=0).  Using \"Missing Resources\" (value=1) will "
          "cause warnings to be generated when required resources or "
          "hardware are not found.  Setting the value to 2, \"Testing "
          "Impacts\", results in both missing resources and 'test "
          "impact' warnings (for example, multiple retries required) "
          "to be reported."), 
       ValueMap {"0", "1", "2", "3"}, 
       Values {"No Warnings", "Missing Resources", "Testing Impacts",
          "All Warnings"}, 
       ModelCorrespondence { "CIM_DiagnosticSetting.TestWarningLevel",
          "CIM_DiagnosticSettingRecord.LogOptions"} ]
   uint16 TestWarningLevel;
};

// ==================================================================
// CorrespondingSettingsRecord
// ==================================================================
   [Association, Experimental, Version ("2.7.1000"), Description (
       "CorrespondingSettingsRecord is used to tie a log record to its "
       "corresponding setting data record.") ]
class CIM_CorrespondingSettingsRecord {

      [Key, Description (
          "The record containing the result data.") ]
   CIM_DiagnosticRecord REF DataRecord;

      [Key, Description (
          "The record containing the DiagnosticSetting data that were "
          "used when the result was created.") ]
   CIM_DiagnosticSettingRecord REF SettingsRecord;
};

// ==================================================================
// AvailableDiagnosticService
// ==================================================================
   [Association, Experimental, Version ("2.7.1000"), Description (
       "This is an association class that relates a DiagnosticService "
       "to a ManagedElement.  Consumers wishing to 'diagnose' a "
       "particular Element could query this association to determine "
       "what services are available.") ]
class CIM_AvailableDiagnosticService : CIM_ServiceAvailableToElement {

      [Override ("ServiceProvided"), Description (
          "The diagnostic service that is available to a "
          "ManagedElement.") ]
   CIM_DiagnosticService REF ServiceProvided;

      [Override ("UserOfService"), Description (
          "The ManagedElement that may use the Service.") ]
   CIM_ManagedElement REF UserOfService;

      [Description (
          "Estimated magnitude of time to perform the referenced "
          "DiagnosticService on the referenced ManagedElement.\n"
          "Since the processing speed of a system can vary immensely "
          "due to a variety of factors (e.g., processor speed), this "
          "property takes on values that are a statement of magnitude, "
          "not absolute time.  If greater accuracy can be provided, a "
          "quantification may be specified in the corresponding "
          "integer property, EstimatedDurationQualifier.\n"
          "Since execution times could vary by Element, this property "
          "is located in the association between the two entities."), 
       ValueMap {"0", "2", "3", "4", "5", "6"}, 
       Values {"Unknown", "Milliseconds", "Seconds", "Minutes",
          "Hours", "Days"}, 
       ModelCorrespondence { 
          "AvailableDiagnosticService.EstimatedDurationQualifier"} ]
   uint16 EstimatedDurationOfService;

      [Description (
          "EstimatedDurationQualifier can be used to further quantify "
          "the magnitude of time to perform the service."), 
       ModelCorrespondence { 
          "AvailableDiagnosticService.EstimatedDurationOfService"} ]
   uint32 EstimatedDurationQualifier;
};


// ===================================================================
// end of file
// ===================================================================