(file) Return to Device_CoolingAndPower.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM29

  1 a.dunfey 1.1 // ===================================================================
  2              // Title: Device_CoolingAndPower
  3              // $State: Exp $
  4              // $Date: 2004/11/29 18:31:42 $
  5              // $RCSfile: Device_CoolingAndPower.mof,v $
  6              // $Revision: 1.2.2.3 $
  7              // ===================================================================
  8              //#pragma inLine ("Includes/copyright.inc")
  9              // Copyright 1998-2005 Distributed Management Task Force, Inc. (DMTF).
 10              // All rights reserved.
 11              // DMTF is a not-for-profit association of industry members dedicated
 12              // to promoting enterprise and systems management and interoperability.
 13              // DMTF specifications and documents may be reproduced for uses
 14              // consistent with this purpose by members and non-members,
 15              // provided that correct attribution is given.
 16              // As DMTF specifications may be revised from time to time,
 17              // the particular version and release date should always be noted.
 18              // 
 19              // Implementation of certain elements of this standard or proposed
 20              // standard may be subject to third party patent rights, including
 21              // provisional patent rights (herein "patent rights"). DMTF makes
 22 a.dunfey 1.1 // no representations to users of the standard as to the existence
 23              // of such rights, and is not responsible to recognize, disclose, or
 24              // identify any or all such third party patent right, owners or
 25              // claimants, nor for any incomplete or inaccurate identification or
 26              // disclosure of such rights, owners or claimants. DMTF shall have no
 27              // liability to any party, in any manner or circumstance, under any
 28              // legal theory whatsoever, for failure to recognize, disclose, or
 29              // identify any such third party patent rights, or for such party's
 30              // reliance on the standard or incorporation thereof in its product,
 31              // protocols or testing procedures. DMTF shall have no liability to
 32              // any party implementing such standard, whether such implementation
 33              // is foreseeable or not, nor to any patent owner or claimant, and shall
 34              // have no liability or responsibility for costs or losses incurred if
 35              // a standard is withdrawn or modified after publication, and shall be
 36              // indemnified and held harmless by any party implementing the
 37              // standard from any and all claims of infringement by a patent owner
 38              // for such implementations.
 39              // 
 40              // For information about patents held by third-parties which have
 41              // notified the DMTF that, in their opinion, such patent may relate to
 42              // or impact implementations of DMTF standards, visit
 43 a.dunfey 1.1 // http://www.dmtf.org/about/policies/disclosures.php.
 44              //#pragma inLine
 45              // ===================================================================
 46              // Description: The Device Model extends the management concepts that
 47              //              are related to LogicalDevices. This file defines
 48              //              the concepts and classes to manage cooling and
 49              //              supply power to devices.
 50              // 
 51              //              The object classes below are listed in an order that
 52              //              avoids forward references. Required objects, defined
 53              //              by other working groups, are omitted.
 54              // ==================================================================
 55              // Change log for 2.8 Final.
 56              // CR1223 - SysDev Omnibus CR - Minor MOF corrections.
 57              // 
 58              // Change Log for v2.7
 59              // CR621 - Deprecate PackageCooling
 60              // CR622 - Fix the DMI mapping string to include the attribute number
 61              //         for Battery.BatteryStatus, .EstimatedRunTime, .Chemistry,
 62              //           .DesignCapacity, .FullChargeCapacity, .DesignVoltage,
 63              //           .SmartBatteryVersion, & .TimeToFullCharge,
 64 a.dunfey 1.1 //         PowerSupply.Range1InputVoltageLow, .Range1InputVoltageHigh,
 65              //           .Range1InputFrequencyLow, .Range1InputFrequencyHigh,
 66              //           .Range2InputVoltageLow, .Range2InputVoltageHigh,
 67              //           .Range2InputFrequencyLow, .Range2InputFrequencyHigh,
 68              //           .ActiveInputVoltage, .TypeOfRangeSwitching, &
 69              //           .TotalOutputPower
 70              // ==================================================================
 71              
 72              #pragma locale ("en_US")
 73              
 74              
 75              // ===================================================================
 76              // CoolingDevice
 77              // ===================================================================
 78                 [Version ( "2.6.0" ), Description (
 79                     "Capabilities and management of CoolingDevices.")]
 80              class CIM_CoolingDevice : CIM_LogicalDevice {
 81              
 82                    [Description (
 83                        "ActiveCooling is a boolean indicating that the Cooling "
 84                        "Device provides active (as opposed to passive) cooling.")]
 85 a.dunfey 1.1    boolean ActiveCooling;
 86              };
 87              
 88              
 89              // ===================================================================
 90              // Refrigeration
 91              // ===================================================================
 92                 [Version ( "2.6.0" ), Description (
 93                     "Capabilities and management of a Refrigeration CoolingDevice.")]
 94              class CIM_Refrigeration : CIM_CoolingDevice {
 95              };
 96              
 97              
 98              // ===================================================================
 99              // HeatPipe
100              // ===================================================================
101                 [Version ( "2.6.0" ), Description (
102                     "Capabilities and management of a HeatPipe CoolingDevice.")]
103              class CIM_HeatPipe : CIM_CoolingDevice {
104              };
105              
106 a.dunfey 1.1 
107              // ===================================================================
108              // Fan
109              // ===================================================================
110                 [Version ( "2.6.0" ), Description (
111                     "Capabilities and management of a Fan CoolingDevice.")]
112              class CIM_Fan : CIM_CoolingDevice {
113              
114                    [Description (
115                        "Indication of whether the fan supports variable speeds.")]
116                 boolean VariableSpeed;
117              
118                    [Description (
119                        "DesiredSpeed is the currently requested fan speed, defined "
120                        "in Revolutions per Minute, when a variable speed fan is "
121                        "supported (VariableSpeed boolean = TRUE). The current speed "
122                        "is determined via a sensor (CIM_Tachometer) that is "
123                        "associated with the Fan using the CIM_AssociatedSensor "
124                        "relationship."), 
125                     Units ( "Revolutions per Minute" )]
126                 uint64 DesiredSpeed;
127 a.dunfey 1.1 
128                    [Description (
129                        "Requests that the Fan speed be set to the value specified "
130                        "in the method's input parameter. The return value should be "
131                        "0 if the request was successfully executed, 1 if the "
132                        "request is not supported and some other value if an error "
133                        "occurred. In a subclass, the set of possible return codes "
134                        "could be specified, using a ValueMap qualifier on the "
135                        "method. The strings to which the ValueMap contents are "
136                        "'translated' may also be specified in the subclass as a "
137                        "Values array qualifier.")]
138                 uint32 SetSpeed ( 
139                       [IN, Description (
140                           "The desired speed for the fan.")]
141                    uint64 DesiredSpeed); 
142              };
143              
144              
145              // ===================================================================
146              // AssociatedCooling
147              // ===================================================================
148 a.dunfey 1.1    [Association, Version ( "2.6.0" ), Description (
149                     "Many Devices, such as processors or power supplies, require "
150                     "their own cooling devices. This association indicates where "
151                     "fans or other CoolingDevices are specific to a Device, versus "
152                     "providing enclosure or cabinet cooling.")]
153              class CIM_AssociatedCooling : CIM_Dependency {
154              
155                    [Override ( "Antecedent" ), Description (
156                        "The CoolingDevice.")]
157                 CIM_CoolingDevice REF Antecedent;
158              
159                    [Override ( "Dependent" ), Description (
160                        "The LogicalDevice being cooled.")]
161                 CIM_LogicalDevice REF Dependent;
162              };
163              
164              
165              // ===================================================================
166              // Battery
167              // ===================================================================
168                 [Version ( "2.7.0" ), Description (
169 a.dunfey 1.1        "Capabilities and management of the Battery LogicalDevice. This "
170                     "class applies to both batteries in Laptop Systems and other "
171                     "internal/external batteries, such as used in, or as UPSs.")]
172              class CIM_Battery : CIM_LogicalDevice {
173              
174                    [Description (
175                        "Description of the Battery's charge status. Values such as "
176                        "\"Fully Charged\" (value=3) or \"Partially Charged\" (11) "
177                        "can be specified. The value, 10, is not valid in the CIM "
178                        "Schema since in DMI it represents that no battery is "
179                        "installed. In this case, this object should not be "
180                        "instantiated."), 
181                     ValueMap { "1", "2", "3", "4", "5", "6", "7", "8", "9", "10",
182                        "11" }, 
183                     Values { "Other", "Unknown", "Fully Charged", "Low", "Critical",
184                        "Charging", "Charging and High", "Charging and Low",
185                        "Charging and Critical", 
186                        // 10               
187                        "Undefined", "Partially Charged" }, 
188                     MappingStrings { "MIF.DMTF|Portable Battery|003.14" }]
189                 uint16 BatteryStatus;
190 a.dunfey 1.1 
191                    [Description (
192                        "TimeOnBattery indicates the elapsed time in seconds since "
193                        "the ComputerSystem, UPS, ... last switched to battery "
194                        "power, or the time since the System or UPS was last "
195                        "restarted, whichever is less. Zero shall be returned if the "
196                        "Battery is 'on line'."), 
197                     Units ( "Seconds" )]
198                 uint32 TimeOnBattery;
199              
200                    [Description (
201                        "EstimatedRunTime is an estimate in minutes of the time to "
202                        "battery charge depletion under the present load conditions "
203                        "if the utility power is off, or lost and remains off, or a "
204                        "Laptop is disconnected from a power source."), 
205                     Units ( "Minutes" ), 
206                     MappingStrings { "MIF.DMTF|Portable Battery|003.15" }]
207                 uint32 EstimatedRunTime;
208              
209                    [Description (
210                        "An estimate of the percentage of full charge remaining."), 
211 a.dunfey 1.1        Units ( "Percent" ), Gauge]
212                 uint16 EstimatedChargeRemaining;
213              
214                    [Description (
215                        "An enumeration that describes the Battery's chemistry."), 
216                     ValueMap { "1", "2", "3", "4", "5", "6", "7", "8" }, 
217                     Values { "Other", "Unknown", "Lead Acid", "Nickel Cadmium",
218                        "Nickel Metal Hydride", "Lithium-ion", "Zinc air",
219                        "Lithium Polymer" }, 
220                     MappingStrings { "MIF.DMTF|Portable Battery|003.7" }]
221                 uint16 Chemistry;
222              
223                    [Description (
224                        "The design capacity of the battery in mWatt-hours. If this "
225                        "property is not supported, enter 0."), 
226                     Units ( "MilliWattHours" ), 
227                     MappingStrings { "MIF.DMTF|Portable Battery|003.8" }]
228                 uint32 DesignCapacity;
229              
230                    [Description (
231                        "The full charge capacity of the battery in mWatt-hours. "
232 a.dunfey 1.1           "Comparison of this value to the Battery DesignCapacity "
233                        "determines when the Battery requires replacement. A "
234                        "Battery's end of life is typically when the FullCharge "
235                        "Capacity falls below 80% of the DesignCapacity. If this "
236                        "property is not supported, enter 0."), 
237                     Units ( "MilliWattHours" ), 
238                     MappingStrings { "MIF.DMTF|Portable Battery|003.11" }]
239                 uint32 FullChargeCapacity;
240              
241                    [Description (
242                        "The design voltage of the battery in mVolts. If this "
243                        "attribute is not supported, enter 0."), 
244                     Units ( "MilliVolts" ), 
245                     MappingStrings { "MIF.DMTF|Portable Battery|003.9" }]
246                 uint64 DesignVoltage;
247              
248                    [Description (
249                        "The Smart Battery Data Specification version number "
250                        "supported by this Battery. If the Battery does not support "
251                        "this function, the value should be left blank."), 
252                     MaxLen ( 64 ), 
253 a.dunfey 1.1        MappingStrings { "MIF.DMTF|Portable Battery|003.10" }]
254                 string SmartBatteryVersion;
255              
256                    [Description (
257                        "The remaining time to charge the battery fully in minutes "
258                        "at the current charging rate and usage."), 
259                     Units ( "Minutes" ), 
260                     MappingStrings { "MIF.DMTF|Portable Battery|003.16" }]
261                 uint32 TimeToFullCharge;
262              
263                    [Description (
264                        "Indicates the Battery's expected lifetime in minutes, "
265                        "assuming that the Battery is fully charged. This property "
266                        "represents the total expected life of the Battery, not its "
267                        "current remaining life, which is indicated by the "
268                        "EstimatedRunTime property."), 
269                     Units ( "Minutes" )]
270                 uint32 ExpectedLife;
271              
272                    [Description (
273                        "MaxRechargeTime indicates the maximum time, in minutes, to "
274 a.dunfey 1.1           "fully charge the Battery. This property represents the time "
275                        "to recharge a fully depleted Battery, not the current "
276                        "remaining charging time, which is indicated in the "
277                        "TimeToFullCharge property."), 
278                     Units ( "Minutes" )]
279                 uint32 MaxRechargeTime;
280              };
281              
282              
283              // ===================================================================
284              // AssociatedBattery
285              // ===================================================================
286                 [Association, Version ( "2.6.0" ), Description (
287                     "A LogicalDevice may use or require one or more Batteries. This "
288                     "relationship is described by the AssociatedBattery dependency. "
289                     "It is also possible to model the individual Batteries that "
290                     "comprise a UPS, using this association.")]
291              class CIM_AssociatedBattery : CIM_Dependency {
292              
293                    [Override ( "Antecedent" ), Description (
294                        "The Battery.")]
295 a.dunfey 1.1    CIM_Battery REF Antecedent;
296              
297                    [Override ( "Dependent" ), Description (
298                        "The LogicalDevice needing or associated with the Battery.")]
299                 CIM_LogicalDevice REF Dependent;
300              };
301              
302              
303              // ===================================================================
304              // PowerSupply
305              // ===================================================================
306                 [Version ( "2.7.0" ), Description (
307                     "Capabilities and management of the PowerSupply LogicalDevice.")]
308              class CIM_PowerSupply : CIM_LogicalDevice {
309              
310                    [Description (
311                        "Boolean indicating that the PowerSupply is a switching (vs "
312                        "linear) supply.")]
313                 boolean IsSwitchingSupply;
314              
315                    [Description (
316 a.dunfey 1.1           "The low voltage of Input Voltage Range 1 for this Power "
317                        "Supply, in millivolts. A value of 0 denotes 'unknown'."), 
318                     Units ( "MilliVolts" ), 
319                     MappingStrings { "MIF.DMTF|Power Supply|004.7" }]
320                 uint32 Range1InputVoltageLow;
321              
322                    [Description (
323                        "The high voltage of Input Voltage Range 1 for this Power "
324                        "Supply, in millivolts. A value of 0 denotes 'unknown'."), 
325                     Units ( "MilliVolts" ), 
326                     MappingStrings { "MIF.DMTF|Power Supply|004.8" }]
327                 uint32 Range1InputVoltageHigh;
328              
329                    [Description (
330                        "The frequency (in Hertz) at the low end of this Power "
331                        "Supply's Input Frequency Range 1. A value of zero implies "
332                        "DC."), 
333                     Units ( "Hertz" ), 
334                     MappingStrings { "MIF.DMTF|Power Supply|004.17" }]
335                 uint32 Range1InputFrequencyLow;
336              
337 a.dunfey 1.1       [Description (
338                        "The frequency (in Hertz) at the high end of this Power "
339                        "Supply's Input Frequency Range 1. A value of zero implies "
340                        "DC."), 
341                     Units ( "Hertz" ), 
342                     MappingStrings { "MIF.DMTF|Power Supply|004.18" }]
343                 uint32 Range1InputFrequencyHigh;
344              
345                    [Description (
346                        "The low voltage of Input Voltage Range 2 for this Power "
347                        "Supply, in millivolts. A value of 0 denotes 'unknown'."), 
348                     Units ( "MilliVolts" ), 
349                     MappingStrings { "MIF.DMTF|Power Supply|004.11" }]
350                 uint32 Range2InputVoltageLow;
351              
352                    [Description (
353                        "The high voltage of Input Voltage Range 2 for this Power "
354                        "Supply, in millivolts. A value of 0 denotes 'unknown'."), 
355                     Units ( "MilliVolts" ), 
356                     MappingStrings { "MIF.DMTF|Power Supply|004.12" }]
357                 uint32 Range2InputVoltageHigh;
358 a.dunfey 1.1 
359                    [Description (
360                        "The frequency (in Hertz) at the low end of this Power "
361                        "Supply's Input Frequency Range 2. A value of zero implies "
362                        "DC."), 
363                     Units ( "Hertz" ), 
364                     MappingStrings { "MIF.DMTF|Power Supply|004.19" }]
365                 uint32 Range2InputFrequencyLow;
366              
367                    [Description (
368                        "The frequency (in Hertz) at the high end of this Power "
369                        "Supply's Input Frequency Range 2. A value of zero implies "
370                        "DC."), 
371                     Units ( "Hertz" ), 
372                     MappingStrings { "MIF.DMTF|Power Supply|004.20" }]
373                 uint32 Range2InputFrequencyHigh;
374              
375                    [Description (
376                        "ActiveInputVoltage indicates which input voltage range is "
377                        "currently in use. Range 1, 2 or both can be specified using "
378                        "the values 3, 4 or 5, respectively. If the Supply is not "
379 a.dunfey 1.1           "currently drawing power, the value 6 (\"Neither\") can be "
380                        "specified. This information is necessary in the case of a "
381                        "UPS, a subclass of PowerSupply."), 
382                     ValueMap { "1", "2", "3", "4", "5", "6" }, 
383                     Values { "Other", "Unknown", "Range 1", "Range 2", "Both",
384                        "Neither" }, 
385                     MappingStrings { "MIF.DMTF|Power Supply|004.15" }]
386                 uint16 ActiveInputVoltage;
387              
388                    [Description (
389                        "TypeOfRangeSwitching describes the kind of input voltage "
390                        "range switching implemented in this PowerSupply. For "
391                        "example, autoswitching can be specified (value=4)."), 
392                     ValueMap { "1", "2", "3", "4", "5", "6" }, 
393                     Values { "Other", "Unknown", "Manual", "Autoswitch",
394                        "Wide Range", "Not Applicable" }, 
395                     MappingStrings { "MIF.DMTF|Power Supply|004.16" }]
396                 uint16 TypeOfRangeSwitching;
397              
398                    [Description (
399                        "Represents the total output power of the PowerSupply in "
400 a.dunfey 1.1           "milliWatts. 0 denotes 'unknown'."), 
401                     Units ( "MilliWatts" ), 
402                     MappingStrings { "MIF.DMTF|Power Supply|004.21" }]
403                 uint32 TotalOutputPower;
404              };
405              
406              
407              // ===================================================================
408              // SuppliesPower
409              // ===================================================================
410                 [Association, Version ( "2.6.0" ), Description (
411                     "The SuppliesPower relationship indicates that a Device is in "
412                     "the power domain of the referenced PowerSupply or UPS. It "
413                     "indicates which Device(s) are dependent on the PowerSupply, "
414                     "and hence, which Devices are affected if the Supply is lost.")]
415              class CIM_SuppliesPower : CIM_Dependency {
416              
417                    [Override ( "Antecedent" ), Description (
418                        "The Supply providing power.")]
419                 CIM_PowerSupply REF Antecedent;
420              
421 a.dunfey 1.1       [Override ( "Dependent" ), Description (
422                        "A LogicalDevice in the power domain of the Supply.")]
423                 CIM_LogicalDevice REF Dependent;
424              };
425              
426              
427              // ===================================================================
428              // UninterruptiblePowerSupply
429              // ===================================================================
430                 [Version ( "2.6.0" ), Description (
431                     "Capabilities and management of an UninterruptiblePowerSupply. "
432                     "The properties of the UPS Device indicate when incoming power "
433                     "is trimmed or boosted, and the aggregated information of the "
434                     "batteries, generators, etc. that comprise the Device. These "
435                     "individual components (for example, multiple batteries) can "
436                     "also be independently modeled and associated with the UPS.")]
437              class CIM_UninterruptiblePowerSupply : CIM_PowerSupply {
438              
439                    [Override ( "Range1InputVoltageLow" ), Description (
440                        "If the voltage (in millivolts) drops below the value "
441                        "specified by Range1InputVoltageLow, the UPS will compensate "
442 a.dunfey 1.1           "by boosting the voltage using its power source(s). A value "
443                        "of 0 indicates that the voltage at which boosting occurs is "
444                        "'unknown'."), 
445                     Units ( "MilliVolts" )]
446                 uint32 Range1InputVoltageLow;
447              
448                    [Override ( "Range1InputVoltageHigh" ), Description (
449                        "If the voltage (in millivolts) rises above the value "
450                        "specified by Range1InputVoltageHigh, the UPS will "
451                        "compensate by trimming the voltage. A value of 0 indicates "
452                        "that the voltage at which trimming occurs is 'unknown'."), 
453                     Units ( "MilliVolts" )]
454                 uint32 Range1InputVoltageHigh;
455              
456                    [Override ( "Range2InputVoltageLow" ), Description (
457                        "If the voltage (in millivolts) drops below the value "
458                        "specified by Range2InputVoltageLow, the UPS will compensate "
459                        "by boosting the voltage using its power source(s). A value "
460                        "of 0 indicates that the voltage at which boosting occurs is "
461                        "'unknown'."), 
462                     Units ( "MilliVolts" )]
463 a.dunfey 1.1    uint32 Range2InputVoltageLow;
464              
465                    [Override ( "Range2InputVoltageHigh" ), Description (
466                        "If the voltage (in millivolts) rises above the value "
467                        "specified by Range2InputVoltageHigh, the UPS will "
468                        "compensate by trimming the voltage. A value of 0 indicates "
469                        "that the voltage at which trimming occurs is 'unknown'."), 
470                     Units ( "MilliVolts" )]
471                 uint32 Range2InputVoltageHigh;
472              
473                    [Description (
474                        "The indication of the capacity remaining in the UPS' "
475                        "batteries, generator, ... A value of \"Normal\" (2) "
476                        "indicates that the remaining estimated minutes of run-time "
477                        "is greater than the UPS' defined 'low power' state "
478                        "(typically two minutes). A value of \"Low\" (3) indicates "
479                        "that the remaining estimated minutes of run-time is less "
480                        "than or equal to the UPS' defined 'low power' state. A "
481                        "value of \"Depleted\" (4) indicates that the UPS will be "
482                        "unable to sustain the present load when and if the utility "
483                        "power is lost (including the possibility that the utility "
484 a.dunfey 1.1           "power is currently absent)."), 
485                     ValueMap { "1", "2", "3", "4" }, 
486                     Values { "Unknown", "Normal", "Low", "Depleted" }, 
487                     MappingStrings { "MIF.DMTF|UPS Battery|001.1" }]
488                 uint16 RemainingCapacityStatus;
489              
490                    [Description (
491                        "TimeOnBackup indicates the elapsed time in seconds since "
492                        "the UPS last switched to battery power, generator, ... Or, "
493                        "the time since the UPS was last restarted, whichever is "
494                        "less. Zero shall be returned if the UPS is 'on line'."), 
495                     Units ( "Seconds" ), 
496                     MappingStrings { "MIF.DMTF|UPS Battery|001.2" }]
497                 uint32 TimeOnBackup;
498              
499                    [Description (
500                        "EstimatedRunTime is an estimate in minutes of the time to "
501                        "battery, generator, ... depletion under the present load "
502                        "conditions if the utility power is off, or lost and remains "
503                        "off."), 
504                     Units ( "Minutes" ), 
505 a.dunfey 1.1        MappingStrings { "MIF.DMTF|UPS Battery|001.3" }]
506                 uint32 EstimatedRunTime;
507              
508                    [Description (
509                        "An estimate of the percentage of full charge remaining for "
510                        "a UPS (that uses battery technology)."), 
511                     Units ( "Percent" ), Gauge, 
512                     MappingStrings { "MIF.DMTF|UPS Battery|001.4" }]
513                 uint16 EstimatedChargeRemaining;
514              };
515              
516              // ==================================================================
517              // PackageCooling
518              // ==================================================================
519                 [Association, Deprecated { "CIM_PackageDependency" },
520                     Version ( "2.7.0" ), Description (
521                     "Often, a CoolingDevice is installed in a Package such as a "
522                     "Chassis or a Rack, not for a specific Device, but to assist in "
523                     "the cooling of the Package in general. The use of this "
524                     "association has been deprecated. Instead, the more generic "
525                     "PackageDependency relationship should be used.")]
526 a.dunfey 1.1 class CIM_PackageCooling : CIM_PackageDependency {
527              
528                    [Deprecated { "CIM_PackageDependency.Antecedent" },
529                        Override ( "Antecedent" ), Description (
530                        "The CoolingDevice for the Package.")]
531                 CIM_CoolingDevice REF Antecedent;
532              
533                    [Deprecated { "CIM_PackageDependency.Dependent" },
534                        Override ( "Dependent" ), Description (
535                        "The PhysicalPackage whose environment is cooled.")]
536                 CIM_PhysicalPackage REF Dependent;
537              };
538              
539              
540              // ===================================================================
541              // end of file
542              // ===================================================================

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2