(file) Return to CIM_StorageHardwareID.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / User

File: [Pegasus] / pegasus / Schemas / CIM231 / DMTF / User / CIM_StorageHardwareID.mof (download)
Revision: 1.1, Tue Jan 24 13:50:37 2012 UTC (12 years, 5 months ago) by marek
Branch: MAIN
CVS Tags: preBug9676, postBug9676, TASK-TASK_PEP362_RestfulService_branch-root, TASK-TASK_PEP362_RestfulService_branch-merged_out_from_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_to_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_from_branch, TASK-TASK_PEP362_RestfulService_branch-branch, TASK-PEP362_RestfulService-root, TASK-PEP362_RestfulService-merged_out_to_branch, TASK-PEP362_RestfulService-merged_out_from_trunk, TASK-PEP362_RestfulService-merged_in_to_trunk, TASK-PEP362_RestfulService-merged_in_from_branch, TASK-PEP362_RestfulService-branch, TASK-PEP317_pullop-merged_out_from_trunk, TASK-PEP317_pullop-merged_in_to_trunk, RELEASE_2_14_1, RELEASE_2_14_0-RC2, RELEASE_2_14_0-RC1, RELEASE_2_14_0, RELEASE_2_14-root, RELEASE_2_14-branch, RELEASE_2_13_0-RC2, RELEASE_2_13_0-RC1, RELEASE_2_13_0-FC, RELEASE_2_13_0, RELEASE_2_13-root, RELEASE_2_13-branch, RELEASE_2_12_1-RC1, RELEASE_2_12_1, RELEASE_2_12_0-RC1, RELEASE_2_12_0-FC, RELEASE_2_12_0, RELEASE_2_12-root, RELEASE_2_12-branch, HEAD, CIMRS_WORK_20130824
Branch point for: TASK-PEP317_pullop-branch
BUG#:9155
TITLE: Upgrade Pegasus to Include the CIM 2.31 Schema in CVS

DESCRIPTION:

// Copyright (c) 2005 DMTF.  All rights reserved.
   [Version ( "2.13.0" ), 
    UMLPackagePath ( "CIM::User::StorageHardwareID" ), 
    Description ( 
       "CIM_StorageHardwareID is a hardware ID that serves as an "
       "authorization subject. Example are host controller IDs that "
       "serve as authorization subjects in disk array LUN Masking." )]
class CIM_StorageHardwareID : CIM_Identity {

      [Required, Description ( "The hardware worldwide unique ID." ), 
       MaxLen ( 256 ), 
       ModelCorrespondence { "CIM_StorageHardwareID.IDType" }]
   string StorageID;

      [Required, Description ( 
          "The type of the ID property. iSCSI IDs may use one of "
          "three iSCSI formats - iqn, eui, or naa. This three "
          "letter format is the name prefix; so a single iSCSI type "
          "is provided here, the prefix can be used to further "
          "refine the format." ), 
       ValueMap { "1", "2", "3", "4", "5", "6" }, 
       Values { "Other", "PortWWN", "NodeWWN", "Hostname", 
          "iSCSI Name", "SwitchWWN" }, 
       ModelCorrespondence { "CIM_StorageHardwareID.StorageID" }]
   uint16 IDType;

      [Description ( "The ID type when IDType is \"Other\"." )]
   string OtherIDType;


};

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2