(file) Return to CIM_GatewayPathID.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / User

File: [Pegasus] / pegasus / Schemas / CIM231 / DMTF / User / CIM_GatewayPathID.mof (download)
Revision: 1.1, Tue Jan 24 13:50:36 2012 UTC (12 years, 5 months ago) by marek
Branch: MAIN
CVS Tags: preBug9676, postBug9676, TASK-TASK_PEP362_RestfulService_branch-root, TASK-TASK_PEP362_RestfulService_branch-merged_out_from_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_to_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_from_branch, TASK-TASK_PEP362_RestfulService_branch-branch, TASK-PEP362_RestfulService-root, TASK-PEP362_RestfulService-merged_out_to_branch, TASK-PEP362_RestfulService-merged_out_from_trunk, TASK-PEP362_RestfulService-merged_in_to_trunk, TASK-PEP362_RestfulService-merged_in_from_branch, TASK-PEP362_RestfulService-branch, TASK-PEP317_pullop-merged_out_from_trunk, TASK-PEP317_pullop-merged_in_to_trunk, RELEASE_2_14_1, RELEASE_2_14_0-RC2, RELEASE_2_14_0-RC1, RELEASE_2_14_0, RELEASE_2_14-root, RELEASE_2_14-branch, RELEASE_2_13_0-RC2, RELEASE_2_13_0-RC1, RELEASE_2_13_0-FC, RELEASE_2_13_0, RELEASE_2_13-root, RELEASE_2_13-branch, RELEASE_2_12_1-RC1, RELEASE_2_12_1, RELEASE_2_12_0-RC1, RELEASE_2_12_0-FC, RELEASE_2_12_0, RELEASE_2_12-root, RELEASE_2_12-branch, HEAD, CIMRS_WORK_20130824
Branch point for: TASK-PEP317_pullop-branch
BUG#:9155
TITLE: Upgrade Pegasus to Include the CIM 2.31 Schema in CVS

DESCRIPTION:

// Copyright (c) 2005 DMTF.  All rights reserved.
// <change cr="DMTFCR01299" type = "change"> Add iSCSI support to the
// enum of ID Types used for SCSI LUN Masking </change>
// <change cr="ArchCR00066.004" type="add">Add UmlPackagePath
// qualifier values to CIM Schema.</change>
// ==================================================================
//  CIM_GatewayPathID
// ==================================================================
   [Version ( "2.8.1000" ), 
    UMLPackagePath ( "CIM::User::StorageHardwareID" ), 
    Description ( 
       "GatewayPathID extends StorageHardwareID to name a path segment "
       "defined by the end identities, HardwareID and GatewayID. The "
       "purpose is to describe Identity to allow access control to be "
       "applied to a particular path segment. Think of the element "
       "identified by GatewayPathID as a Gateway between a non-trusted "
       "world and a trusted world." )]
class CIM_GatewayPathID : CIM_StorageHardwareID {

      [Required, Description ( 
          "The ID representing the Gateway for a path segment from "
          "the element identified in the HardwareID property to the "
          "Gateway." ), 
       ModelCorrespondence { "CIM_GatewayPathID.GatewayIDType", 
          "CIM_GatewayPathID.OtherGatewayIDType" }]
   string GatewayID;

      [Required, Description ( 
          "The type of the ID property. iSCSI GatewayIDs may use "
          "one of three iSCSI formats - iqn, eui, or naa. This "
          "three letter format is the name prefix; so a single "
          "iSCSI type is provided here, the prefix can be used to "
          "further refine the format." ), 
       ValueMap { "1", "2", "3", "4", "5" }, 
       Values { "Other", "PortWWN", "NodeWWN", "Hostname", 
          "iSCSI Name" }, 
       ModelCorrespondence { "CIM_GatewayPathID.GatewayID" }]
   uint16 GatewayIDType;

      [Description ( 
          "The gateway ID type when Gateway IDType is \"Other\"." ), 
       ModelCorrespondence { "CIM_GatewayPathID.GatewayID" }]
   string OtherGatewayIDType;


};

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2