version 1.1.2.1, 2012/01/24 13:50:09
|
version 1.1.2.2, 2012/02/15 17:46:24
|
|
|
|
// Copyright (c) 2005 DMTF. All rights reserved. |
|
// <change cr="CIMCoreCR00735.001" type ="change">Update of |
|
// descriptions based on Tech Edit review.</ |
|
// <change cr="ArchCR00066.004" type="add">Add UmlPackagePath |
|
// qualifier values to CIM Schema.</change> |
|
// <change cr="ArchCR00089.003" type="add">Add PUnit qualifier values |
|
// to Units qualifier values.</change> |
|
// ================================================================== |
|
// CIM_UninterruptiblePowerSupply |
|
// ================================================================== |
|
[Version ( "2.10.0" ), |
|
UMLPackagePath ( "CIM::Device::CoolingAndPower" ), |
|
Description ( |
|
"Capabilities and management of an UninterruptiblePowerSupply. " |
|
"The properties of the UPS Device indicate when incoming power " |
|
"is trimmed or boosted, and the aggregated information of the " |
|
"batteries, generators, and so on that comprise the Device. " |
|
"These individual components (for example, multiple batteries) " |
|
"can also be independently modeled and associated with the UPS." )] |
|
class CIM_UninterruptiblePowerSupply : CIM_PowerSupply { |
|
|
|
[Override ( "Range1InputVoltageLow" ), |
|
Description ( |
|
"If the voltage (in millivolts) drops below the value " |
|
"specified by Range1InputVoltageLow, the UPS will " |
|
"compensate by boosting the voltage using its power " |
|
"sources. A value of 0 indicates that the voltage at " |
|
"which boosting occurs is \'unknown\'." ), |
|
Units ( "MilliVolts" ), |
|
PUnit ( "volt * 10^-3" )] |
|
uint32 Range1InputVoltageLow; |
|
|
|
[Override ( "Range1InputVoltageHigh" ), |
|
Description ( |
|
"If the voltage (in millivolts) rises above the value " |
|
"specified by Range1InputVoltageHigh, the UPS will " |
|
"compensate by trimming the voltage. A value of 0 " |
|
"indicates that the voltage at which trimming occurs is " |
|
"\'unknown\'." ), |
|
Units ( "MilliVolts" ), |
|
PUnit ( "volt * 10^-3" )] |
|
uint32 Range1InputVoltageHigh; |
|
|
|
[Override ( "Range2InputVoltageLow" ), |
|
Description ( |
|
"If the voltage (in millivolts) drops below the value " |
|
"specified by Range2InputVoltageLow, the UPS will " |
|
"compensate by boosting the voltage using its power " |
|
"sources. A value of 0 indicates that the voltage at " |
|
"which boosting occurs is \'unknown\'." ), |
|
Units ( "MilliVolts" ), |
|
PUnit ( "volt * 10^-3" )] |
|
uint32 Range2InputVoltageLow; |
|
|
|
[Override ( "Range2InputVoltageHigh" ), |
|
Description ( |
|
"If the voltage (in millivolts) rises above the value " |
|
"specified by Range2InputVoltageHigh, the UPS will " |
|
"compensate by trimming the voltage. A value of 0 " |
|
"indicates that the voltage at which trimming occurs is " |
|
"\'unknown\'." ), |
|
Units ( "MilliVolts" ), |
|
PUnit ( "volt * 10^-3" )] |
|
uint32 Range2InputVoltageHigh; |
|
|
|
[Description ( |
|
"The indication of the capacity that remains in the UPS " |
|
"batteries, generator, and so on. A value of \"Normal\" " |
|
"(2) indicates that the remaining estimated minutes of " |
|
"run-time are greater than the \'low power\' state " |
|
"defined for the UPS (typically two minutes). A value of " |
|
"\"Low\" (3) indicates that the remaining estimated " |
|
"minutes of run-time are less than or equal to the " |
|
"defined \'low power\' state of the device. A value of " |
|
"\"Depleted\" (4) indicates that the UPS will be unable " |
|
"to sustain the present load when and if the utility " |
|
"power is lost (including the possibility that the " |
|
"utility power is currently absent)." ), |
|
ValueMap { "1", "2", "3", "4" }, |
|
Values { "Unknown", "Normal", "Low", "Depleted" }, |
|
MappingStrings { "MIF.DMTF|UPS Battery|001.1" }] |
|
uint16 RemainingCapacityStatus; |
|
|
|
[Description ( |
|
"TimeOnBackup indicates the elapsed time in seconds since " |
|
"the UPS last switched to battery power, generator, or so " |
|
"on or the time since the UPS was last restarted, " |
|
"whichever is less. 0 is returned if the UPS is \'on " |
|
"line\'." ), |
|
Units ( "Seconds" ), |
|
MappingStrings { "MIF.DMTF|UPS Battery|001.2" }, |
|
PUnit ( "second" )] |
|
uint32 TimeOnBackup; |
|
|
|
[Description ( |
|
"EstimatedRunTime is an estimate in minutes of the time " |
|
"that depletion of the battery, generator, or other " |
|
"device, will occur under the present load conditions if " |
|
"the utility power is off or is lost and remains off." ), |
|
Units ( "Minutes" ), |
|
MappingStrings { "MIF.DMTF|UPS Battery|001.3" }, |
|
PUnit ( "minute" )] |
|
uint32 EstimatedRunTime; |
|
|
|
[Description ( |
|
"An estimate of the percentage of full charge remaining " |
|
"for a UPS (that uses battery technology)." ), |
|
Units ( "Percent" ), |
|
Gauge, MappingStrings { "MIF.DMTF|UPS Battery|001.4" }, |
|
PUnit ( "percent" )] |
|
uint16 EstimatedChargeRemaining; |
|
|
|
|
|
}; |