   //  CIM_UninterruptiblePowerSupply
   // ==================================================================
      [Version ( "2.10.0" ),
       UMLPackagePath ( "CIM::Device::CoolingAndPower" ),
       Description (
          "Capabilities and management of an UninterruptiblePowerSupply. "
          "The properties of the UPS Device indicate when incoming power "
          "is trimmed or boosted, and the aggregated information of the "
          "batteries, generators, and so on that comprise the Device. "
          "These individual components (for example, multiple batteries) "
          "can also be independently modeled and associated with the UPS." )]
   class CIM_UninterruptiblePowerSupply : CIM_PowerSupply {
   
         [Override ( "Range1InputVoltageLow" ),
          Description (
             "If the voltage (in millivolts) drops below the value "
             "specified by Range1InputVoltageLow, the UPS will "
             "compensate by boosting the voltage using its power "
             "sources. A value of 0 indicates that the voltage at "
             "which boosting occurs is \'unknown\'." ),
          Units ( "MilliVolts" ),
          PUnit ( "volt * 10^-3" )]
      uint32 Range1InputVoltageLow;
   
         [Override ( "Range1InputVoltageHigh" ),
          Description (
             "If the voltage (in millivolts) rises above the value "
             "specified by Range1InputVoltageHigh, the UPS will "
             "compensate by trimming the voltage. A value of 0 "
             "indicates that the voltage at which trimming occurs is "
             "\'unknown\'." ),
          Units ( "MilliVolts" ),
          PUnit ( "volt * 10^-3" )]
      uint32 Range1InputVoltageHigh;
   
         [Override ( "Range2InputVoltageLow" ),
          Description (
             "If the voltage (in millivolts) drops below the value "
             "specified by Range2InputVoltageLow, the UPS will "
             "compensate by boosting the voltage using its power "
             "sources. A value of 0 indicates that the voltage at "
             "which boosting occurs is \'unknown\'." ),
          Units ( "MilliVolts" ),
          PUnit ( "volt * 10^-3" )]
      uint32 Range2InputVoltageLow;
   
         [Override ( "Range2InputVoltageHigh" ),
          Description (
             "If the voltage (in millivolts) rises above the value "
             "specified by Range2InputVoltageHigh, the UPS will "
             "compensate by trimming the voltage. A value of 0 "
             "indicates that the voltage at which trimming occurs is "
             "\'unknown\'." ),
          Units ( "MilliVolts" ),
          PUnit ( "volt * 10^-3" )]
      uint32 Range2InputVoltageHigh;
   
         [Description (
             "The indication of the capacity that remains in the UPS "
             "batteries, generator, and so on. A value of \"Normal\" "
             "(2) indicates that the remaining estimated minutes of "
             "run-time are greater than the \'low power\' state "
             "defined for the UPS (typically two minutes). A value of "
             "\"Low\" (3) indicates that the remaining estimated "
             "minutes of run-time are less than or equal to the "
             "defined \'low power\' state of the device. A value of "
             "\"Depleted\" (4) indicates that the UPS will be unable "
             "to sustain the present load when and if the utility "
             "power is lost (including the possibility that the "
             "utility power is currently absent)." ),
          ValueMap { "1", "2", "3", "4" },
          Values { "Unknown", "Normal", "Low", "Depleted" },
          MappingStrings { "MIF.DMTF|UPS Battery|001.1" }]
      uint16 RemainingCapacityStatus;
   
         [Description (
             "TimeOnBackup indicates the elapsed time in seconds since "
             "the UPS last switched to battery power, generator, or so "
             "on or the time since the UPS was last restarted, "
             "whichever is less. 0 is returned if the UPS is \'on "
             "line\'." ),
          Units ( "Seconds" ),
          MappingStrings { "MIF.DMTF|UPS Battery|001.2" },
          PUnit ( "second" )]
      uint32 TimeOnBackup;
   
         [Description (
             "EstimatedRunTime is an estimate in minutes of the time "
             "that depletion of the battery, generator, or other "
             "device, will occur under the present load conditions if "
             "the utility power is off or is lost and remains off." ),
          Units ( "Minutes" ),
          MappingStrings { "MIF.DMTF|UPS Battery|001.3" },
          PUnit ( "minute" )]
      uint32 EstimatedRunTime;
   
         [Description (
             "An estimate of the percentage of full charge remaining "
             "for a UPS (that uses battery technology)." ),
          Units ( "Percent" ),
          Gauge, MappingStrings { "MIF.DMTF|UPS Battery|001.4" },
          PUnit ( "percent" )]
      uint16 EstimatedChargeRemaining;
   
   
   };