(file) Return to CIM_USBPort.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device

Diff for /pegasus/Schemas/CIM231/DMTF/Device/CIM_USBPort.mof between version 1.1.2.1 and 1.1.2.2

version 1.1.2.1, 2012/01/24 13:50:09 version 1.1.2.2, 2012/02/15 17:46:24
Line 0 
Line 1 
   // Copyright (c) 2005 DMTF.  All rights reserved.
   // <change cr="ArchCR00066.004" type="add">Add UmlPackagePath
   // qualifier values to CIM Schema.</change>
   // ==================================================================
   //  CIM_USBPort
   // ==================================================================
      [Version ( "2.6.0" ),
       UMLPackagePath ( "CIM::Device::USB" ),
       Description ( "A Port on a USBHub." )]
   class CIM_USBPort : CIM_LogicalPort {
   
         [Override ( "Speed" ),
          Description (
             "USB Port Speed in bits per second. This speed is "
             "determined and set by the attached Device. The \'attached "
             "Device\' is indicated using the USBConnection "
             "association. At this time, only several Port speeds are "
             "valid. These are: 1.5Mbps and 12Mbps. The value 0 can "
             "also be specified to indicate that the current speed is "
             "\'unknown\' or 1 to indicate that the speed is \'other\' "
             "than 1.5 or 12Mbps." ),
          ValueMap { "0", "1", "1500000", "12000000" }]
      uint64 Speed;
   
         [Override ( "StatusInfo" ),
          Description (
             "Indicates whether the Port is currently enabled." ),
          ValueMap { "2", "3", "4" },
          Values { "Unknown", "Enabled", "Disabled" }]
      uint16 StatusInfo;
   
         [Override ( "Availability" ),
          Description (
             "Indicates whether the Port is currently Powered." ),
          ValueMap { "2", "3", "7" },
          Values { "Unknown", "Running/Full Power", "Power Off" }]
      uint16 Availability;
   
         [Description (
             "The USB Port\'s power capability. The current "
             "specification defines that 1 or 5 loads can be supported "
             "(values 2 or 3 would be specified, respectively)." ),
          ValueMap { "0", "1", "2", "3" },
          Values { "Unknown", "Other", "1 Unit Load", "5 Unit Loads" }]
      uint16 Power;
   
         [Description (
             "Indicates whether the Port is currently Suspended." )]
      boolean Suspended;
   
         [Description (
             "Indicates whether the Port is disabled due to an "
             "overcurrent event." )]
      boolean Overcurrent;
   
   
   };


Legend:
Removed from v.1.1.2.1  
changed lines
  Added in v.1.1.2.2

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2