(file) Return to CIM_StorageVolume.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device

File: [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device / CIM_StorageVolume.mof (download)
Revision: 1.1.2.2, Wed Feb 15 17:46:24 2012 UTC (12 years, 4 months ago) by karl
Branch: TASK-PEP317_pullop-branch
CVS Tags: TASK_PEP317_1JUNE_2013, TASK-PEP317_pullop-merged_out_to_branch, TASK-PEP317_pullop-merged_in_from_branch, PREAUG25UPDATE, POSTAUG25UPDATE
Changes since 1.1.2.1: +55 -0 lines
BUG#: 99999
TITLE: Task317 Branch -- pull operations. Sync to head of tree

DESCRIPTION: Sync the branch back to the head of cvs tree

// Copyright (c) 2005 DMTF.  All rights reserved.
// <change cr="ArchCR00066.004" type="add">Add UmlPackagePath
// qualifier values to CIM Schema.</change>
// ==================================================================
//  CIM_StorageVolume 
// ==================================================================
   [Version ( "2.13.0" ), 
    UMLPackagePath ( "CIM::Device::StorageExtents" ), 
    Description ( 
       "A StorageVolume is a StorageExtent that is published for use "
       "outside of the scoping System. For SCSI storage target "
       "devices, StorageVolumes are used to represent target Block "
       "devices, (peripheral device type codes 0h (i.e, "
       "direct-access), 4h (i.e., write-once), 5h (i.e., CD/DVD), 7h "
       "(i.e., optical memory), and Eh (i.e., simplified "
       "direct-access).); \n"
       "Stream devices, (peripheral device type codes 1h (i.e., \n"
       "sequential-access) and 3h (i.e., processor).). \n"
       "In these case, StorageVolume.Name will be derived from SCSI "
       "volume as documented in StorageExtent.Nameformat and "
       "NameNamespace Descriptions. \n"
       "\n"
       "The \'Exported\' value from StorageExtent.ExtentStatus[] MUST "
       "be in all instances of StorageVolume to maintain the semantic "
       "of \'published\' described above." )]
class CIM_StorageVolume : CIM_StorageExtent {

      [Override ( "Name" ), 
       Description ( "A unique identifier for the Volume." ), 
       MappingStrings { "ANSI|T10|SCSI SPC-3|8.6" }, 
       ModelCorrespondence { "CIM_StorageVolume.NameFormat" }]
   string Name;

      [Override ( "NameFormat" ), 
       Description ( 
          "A subset of StorageExtent name formats apply to StorageVolumes."
           ), 
       ValueMap { "0", "1", "2", "3", "4", "5", "6", "7", "8", "9", 
          "10", "11" }, 
       Values { "Unknown", "Other", "VPD83NAA6", "VPD83NAA5", 
          "VPD83Type2", "VPD83Type1", "VPD83Type0", "SNVM", 
          "NodeWWN", "NAA", "EUI64", "T10VID" }]
   uint16 NameFormat;

      [Override ( "NameNamespace" ), 
       Description ( 
          "A subset of StorageExtent name spaces apply to StorageVolume."
           ), 
       ValueMap { "0", "1", "2", "3", "4", "5", "6", "7" }, 
       Values { "Unknown", "Other", "VPD83Type3", "VPD83Type2", 
          "VPD83Type1", "VPD80", "NodeWWN", "SNVM" }]
   uint16 NameNamespace;


};

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2