(file) Return to CIM_NetworkPortCapabilities.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device

File: [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device / CIM_NetworkPortCapabilities.mof (download)
Revision: 1.1, Tue Jan 24 13:50:08 2012 UTC (12 years, 5 months ago) by marek
Branch: MAIN
CVS Tags: preBug9676, postBug9676, TASK-TASK_PEP362_RestfulService_branch-root, TASK-TASK_PEP362_RestfulService_branch-merged_out_from_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_to_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_from_branch, TASK-TASK_PEP362_RestfulService_branch-branch, TASK-PEP362_RestfulService-root, TASK-PEP362_RestfulService-merged_out_to_branch, TASK-PEP362_RestfulService-merged_out_from_trunk, TASK-PEP362_RestfulService-merged_in_to_trunk, TASK-PEP362_RestfulService-merged_in_from_branch, TASK-PEP362_RestfulService-branch, TASK-PEP317_pullop-merged_out_from_trunk, TASK-PEP317_pullop-merged_in_to_trunk, RELEASE_2_14_1, RELEASE_2_14_0-RC2, RELEASE_2_14_0-RC1, RELEASE_2_14_0, RELEASE_2_14-root, RELEASE_2_14-branch, RELEASE_2_13_0-RC2, RELEASE_2_13_0-RC1, RELEASE_2_13_0-FC, RELEASE_2_13_0, RELEASE_2_13-root, RELEASE_2_13-branch, RELEASE_2_12_1-RC1, RELEASE_2_12_1, RELEASE_2_12_0-RC1, RELEASE_2_12_0-FC, RELEASE_2_12_0, RELEASE_2_12-root, RELEASE_2_12-branch, HEAD, CIMRS_WORK_20130824
Branch point for: TASK-PEP317_pullop-branch
BUG#:9155
TITLE: Upgrade Pegasus to Include the CIM 2.31 Schema in CVS

DESCRIPTION:

// Copyright (c) 2009 DMTF.  All rights reserved.
   [Version ( "2.22.0" ), 
    UMLPackagePath ( "CIM::Device::Ports" ), 
    Description ( 
       "NetworkPortCapabilities describes the capabilities supported "
       "for properties that are configurable in NetworkPort." )]
class CIM_NetworkPortCapabilities : CIM_LogicalPortCapabilities {

      [Description ( 
          "Boolean that indicates whether the Speed can be configured."
           ), 
       ModelCorrespondence { 
          "CIM_NetworkPortCapabilities.PortSpeedsSupported" }]
   boolean SpeedConfigurable = false;

      [Description ( 
          "List of supported port speeds that can be configured on "
          "NetworkPort.Speed." ), 
       ModelCorrespondence { "CIM_NetworkPort.Speed" }]
   uint64 PortSpeedsSupported[];

      [Description ( 
          "Boolean indicating whether the NetworkPort can be "
          "configured to connect to specific Networks." ), 
       ModelCorrespondence { "CIM_NetworkPortSettings.NetworkIDs" }]
   boolean NetworkIDsConfigurable;

      [Description ( 
          "The format that is expected to populate the NetworkIds "
          "for the associated NetworkPortSettings.list of supported "
          "LinkTechnologies of the NetworkPort is defined in the "
          "NetworkPortCapabilities." ), 
       ValueMap { "2", "..", "32768..65535" }, 
       Values { "Virtual Fabric ID", "DMTF Reserved", 
          "Vendor Reserved" }, 
       ModelCorrespondence { "CIM_NetworkPortSettings.NetworkIDs" }]
   uint16 NetworkIDsFormat;

      [Description ( 
          "List of the LinkTechnologies supported by the the NetworkPort."
           ), 
       ValueMap { "2", "3", "4", "5", "6", "7", "8", "9", "10", 
          "11", ".." }, 
       Values { "Ethernet", "IB", "FC", "FDDI", "ATM", "Token Ring", 
          "Frame Relay", "Infrared", "BlueTooth", "Wireless LAN", 
          "DMTF Reserved" }, 
       ModelCorrespondence { "CIM_NetworkPortSettings.NetworkIDs", 
          "CIM_NetworkPort.LinkTechnology" }]
   uint16 LinkTechnologiesSupported[];


};

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2