(file) Return to CIM_NetworkPortCapabilities.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device

Diff for /pegasus/Schemas/CIM231/DMTF/Device/CIM_NetworkPortCapabilities.mof between version 1.1.2.1 and 1.1.2.2

version 1.1.2.1, 2012/01/24 13:50:08 version 1.1.2.2, 2012/02/15 17:46:22
Line 0 
Line 1 
   // Copyright (c) 2009 DMTF.  All rights reserved.
      [Version ( "2.22.0" ),
       UMLPackagePath ( "CIM::Device::Ports" ),
       Description (
          "NetworkPortCapabilities describes the capabilities supported "
          "for properties that are configurable in NetworkPort." )]
   class CIM_NetworkPortCapabilities : CIM_LogicalPortCapabilities {
   
         [Description (
             "Boolean that indicates whether the Speed can be configured."
              ),
          ModelCorrespondence {
             "CIM_NetworkPortCapabilities.PortSpeedsSupported" }]
      boolean SpeedConfigurable = false;
   
         [Description (
             "List of supported port speeds that can be configured on "
             "NetworkPort.Speed." ),
          ModelCorrespondence { "CIM_NetworkPort.Speed" }]
      uint64 PortSpeedsSupported[];
   
         [Description (
             "Boolean indicating whether the NetworkPort can be "
             "configured to connect to specific Networks." ),
          ModelCorrespondence { "CIM_NetworkPortSettings.NetworkIDs" }]
      boolean NetworkIDsConfigurable;
   
         [Description (
             "The format that is expected to populate the NetworkIds "
             "for the associated NetworkPortSettings.list of supported "
             "LinkTechnologies of the NetworkPort is defined in the "
             "NetworkPortCapabilities." ),
          ValueMap { "2", "..", "32768..65535" },
          Values { "Virtual Fabric ID", "DMTF Reserved",
             "Vendor Reserved" },
          ModelCorrespondence { "CIM_NetworkPortSettings.NetworkIDs" }]
      uint16 NetworkIDsFormat;
   
         [Description (
             "List of the LinkTechnologies supported by the the NetworkPort."
              ),
          ValueMap { "2", "3", "4", "5", "6", "7", "8", "9", "10",
             "11", ".." },
          Values { "Ethernet", "IB", "FC", "FDDI", "ATM", "Token Ring",
             "Frame Relay", "Infrared", "BlueTooth", "Wireless LAN",
             "DMTF Reserved" },
          ModelCorrespondence { "CIM_NetworkPortSettings.NetworkIDs",
             "CIM_NetworkPort.LinkTechnology" }]
      uint16 LinkTechnologiesSupported[];
   
   
   };


Legend:
Removed from v.1.1.2.1  
changed lines
  Added in v.1.1.2.2

No CVS admin address has been configured
Powered by
ViewCVS 0.9.2