File: [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device / CIM_LogicalPortSettings.mof
(download)
Revision: 1.1, Tue Jan 24 13:50:08 2012 UTC (12 years, 5 months ago) by marek Branch: MAIN CVS Tags: preBug9676, postBug9676, TASK-TASK_PEP362_RestfulService_branch-root, TASK-TASK_PEP362_RestfulService_branch-merged_out_from_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_to_trunk, TASK-TASK_PEP362_RestfulService_branch-merged_in_from_branch, TASK-TASK_PEP362_RestfulService_branch-branch, TASK-PEP362_RestfulService-root, TASK-PEP362_RestfulService-merged_out_to_branch, TASK-PEP362_RestfulService-merged_out_from_trunk, TASK-PEP362_RestfulService-merged_in_to_trunk, TASK-PEP362_RestfulService-merged_in_from_branch, TASK-PEP362_RestfulService-branch, TASK-PEP317_pullop-merged_out_from_trunk, TASK-PEP317_pullop-merged_in_to_trunk, RELEASE_2_14_1, RELEASE_2_14_0-RC2, RELEASE_2_14_0-RC1, RELEASE_2_14_0, RELEASE_2_14-root, RELEASE_2_14-branch, RELEASE_2_13_0-RC2, RELEASE_2_13_0-RC1, RELEASE_2_13_0-FC, RELEASE_2_13_0, RELEASE_2_13-root, RELEASE_2_13-branch, RELEASE_2_12_1-RC1, RELEASE_2_12_1, RELEASE_2_12_0-RC1, RELEASE_2_12_0-FC, RELEASE_2_12_0, RELEASE_2_12-root, RELEASE_2_12-branch, HEAD, CIMRS_WORK_20130824 Branch point for: TASK-PEP317_pullop-branch BUG#:9155 TITLE: Upgrade Pegasus to Include the CIM 2.31 Schema in CVS DESCRIPTION: |
// Copyright (c) 2005 DMTF. All rights reserved. [Version ( "2.11.0" ), UMLPackagePath ( "CIM::Device::Ports" ), Description ( "A LogicalPort may be configured via the LogicalPortSettings " "class. The configuration changes are expected to be stored to " "non-volatile memory." )] class CIM_LogicalPortSettings : CIM_SettingData { [Write, Description ( "The requested bandwidth of the Port in Bits per Second. " "The actual bandwidth is reported in LogicalPort.Speed." ), Units ( "Bits per Second" ), MappingStrings { "FC-SWAPI.INCITS-T11|UcPortConfigSetLinkSpeed" }, ModelCorrespondence { "CIM_LogicalPort.Speed" }, PUnit ( "bit / second" )] uint64 RequestedSpeed; [Write, Description ( "A boolean indicating whether the LogicalPort should " "automatically negotiate an optimal bandwidth (TRUE), or " "attempt to communicate only at the RequestedSpeed " "(FALSE). The actual bandwidth is reported in " "LogicalPort.Speed. Changing this value to (FALSE) may " "cause the OperationalStatus to change to [stopped] if " "the RequestedSpeed is not compatible with the attached " "device \n" "Check LogicalPortCapabilities.AutoSenseSpeedConfigurable " "to see if this value may be changed." ), MappingStrings { "FC-SWAPI.INCITS-T11|UcPortConfigSetLinkSpeed" }, ModelCorrespondence { "CIM_LogicalPort.Speed", "CIM_LogicalPortCapabilities.AutoSenseSpeedConfigurable" }] boolean AutoSenseSpeed; };
No CVS admin address has been configured |
Powered by ViewCVS 0.9.2 |