(file) Return to CIM_AlarmDevice.mof CVS log (file) (dir) Up to [Pegasus] / pegasus / Schemas / CIM231 / DMTF / Device

  1 marek 1.1 // Copyright (c) 2005 DMTF.  All rights reserved.
  2           // <change cr="ArchCR00066.004" type="add">Add UmlPackagePath
  3           // qualifier values to CIM Schema.</change>
  4           // ==================================================================
  5           //  CIM_AlarmDevice 
  6           // ==================================================================
  7              [Version ( "2.8.0" ), 
  8               UMLPackagePath ( "CIM::Device::Sensors" ), 
  9               Description ( 
 10                  "An AlarmDevice is a type of Device that emits audible or "
 11                  "visible indications related to a problem situation." )]
 12           class CIM_AlarmDevice : CIM_LogicalDevice {
 13           
 14                 [Description ( "Boolean indicating that the Alarm is audible." )]
 15              boolean AudibleAlarm;
 16           
 17                 [Description ( "Boolean indicating that the Alarm is visible." )]
 18              boolean VisibleAlarm;
 19           
 20                 [Description ( 
 21                     "Boolean indicating that the Alarm causes motion of the Device."
 22 marek 1.1            )]
 23              boolean MotionAlarm;
 24           
 25                 [Description ( 
 26                     "Urgency is an enumerated value that indicates the "
 27                     "relative frequency at which the Alarm flashes, vibrates "
 28                     "and/or emits audible tones." ), 
 29                  ValueMap { "0", "1", "2", "3", "4", "5", "6" }, 
 30                  Values { "Unknown", "Other", "Not Supported", 
 31                     "Informational", "Non-Critical", "Critical", 
 32                     "Unrecoverable" }]
 33              uint16 Urgency;
 34           
 35                 [Description ( "The current state of the alarm." ), 
 36                  ValueMap { "0", "1", "2", "3" }, 
 37                  Values { "Unknown", "Off", "Steady", "Alternating" }]
 38              uint16 AlarmState;
 39           
 40                 [Description ( 
 41                     "True indicates that the audio of an AlarmState indicator "
 42                     "has been disabled (i.e. muted). A disabled state here "
 43 marek 1.1           "does not imply that the AlarmState is off." )]
 44              boolean AudioIndicatorIsDisabled;
 45           
 46                 [Description ( 
 47                     "True indicates that the visual of an AlarmState "
 48                     "indicator has been disabled (i.e. dimmed). A disabled "
 49                     "state here does not imply that the AlarmState is off." )]
 50              boolean VisualIndicatorIsDisabled;
 51           
 52                 [Description ( 
 53                     "True indicates that the motion of an AlarmState "
 54                     "indicator has been disabled (i.e. stopped). A disabled "
 55                     "state here does not imply that the AlarmState is off." )]
 56              boolean MotionIndicatorIsDisabled;
 57           
 58           
 59                 [Description ( 
 60                     "SetAlarmState is a method for defining the current state "
 61                     "of the Alarm. Its input parameter, RequestedAlarmState, "
 62                     "is specified using the Values list of AlarmDevice\'s "
 63                     "AlarmState property. SetAlarmState returns 0 if the "
 64 marek 1.1           "request is successfully implemented, 1 if the specified "
 65                     "RequestedAlarm State is not supported, and some other "
 66                     "value if any other error occurred. In a subclass, the "
 67                     "set of possible return codes should be specified using a "
 68                     "ValueMap qualifier on the method. The strings to which "
 69                     "the ValueMap contents are \'translated\' should be "
 70                     "specified as a Values array qualifier." )]
 71              uint32 SetAlarmState(
 72                    [IN, Description ( "The desired state for the alarm." ), 
 73                     ValueMap { "0", "1", "2", "3" }, 
 74                     Values { "Unknown", "Off", "Steady", "Alternating" }]
 75                 uint16 RequestedAlarmState);
 76           
 77                 [Description ( 
 78                     "SetAlarmIndicator is a method for enabling or disabling "
 79                     "the indicator of the AlarmState function, without "
 80                     "changing the current AlarmState. It has 3 input "
 81                     "parameters, Audio Indicator, VisualIndicator and "
 82                     "MotionIndicator. For all of the input parameters, a "
 83                     "value of 0 indicates no change to the AlarmState "
 84                     "indicator, 1 indicates Disable, and 2 indicates Enable. "
 85 marek 1.1           "The method returns 0 if the request is successfully "
 86                     "implemented, 1 if the specified request is not "
 87                     "supported, and some other value if any other error "
 88                     "occurred. In a subclass, the set of possible return "
 89                     "codes should be specified using a ValueMap qualifier on "
 90                     "the method. The strings to which the ValueMap contents "
 91                     "are \'translated\' should be specified as a Values array "
 92                     "qualifier." )]
 93              uint32 SetAlarmIndicator(
 94                    [IN, Description ( "The state for the audio indicator." ), 
 95                     ValueMap { "0", "1", "2" }, 
 96                     Values { "No Change", "Disable", "Enable" }]
 97                 uint16 AudioIndicator, 
 98                    [IN, Description ( "The state for the visual indicator." ), 
 99                     ValueMap { "0", "1", "2" }, 
100                     Values { "No Change", "Disable", "Enable" }]
101                 uint16 VisualIndicator, 
102                    [IN, Description ( "The state for the motion indicator." ), 
103                     ValueMap { "0", "1", "2" }, 
104                     Values { "No Change", "Disable", "Enable" }]
105                 uint16 MotionIndicator);
106 marek 1.1 
107                 [Description ( 
108                     "SetUrgency is a method for defining the desired urgency "
109                     "level for the Alarm. Its input parameter, "
110                     "RequestedUrgency, is specified using the Values list of "
111                     "AlarmDevice\'s Urgency property. SetUrgency returns 0 if "
112                     "the request is successfully implemented, 1 if the "
113                     "specified Urgency level is not supported, and some other "
114                     "value if any other error occurred. In a subclass, the "
115                     "set of possible return codes should be specified using a "
116                     "ValueMap qualifier on the method. The strings to which "
117                     "the ValueMap contents are \'translated\' should be "
118                     "specified as a Values array qualifier." )]
119              uint32 SetUrgency(
120                    [IN, Description ( "Desired urgency for the alarm." ), 
121                     ValueMap { "1", "3", "4", "5", "6" }, 
122                     Values { "Other", "Informational", "Non-Critical", 
123                        "Critical", "Unrecoverable" }]
124                 uint16 RequestedUrgency);
125           
126           };