version 1.1.2.1, 2012/01/24 13:50:00
|
version 1.1.2.2, 2012/02/15 17:46:14
|
|
|
|
// Copyright (c) 2009 DMTF. All rights reserved. |
|
[Version ( "2.23.0" ), |
|
UMLPackagePath ( "CIM::Core::PowerMgmt" ), |
|
Description ( |
|
"A class derived from Capabilities that describes the power " |
|
"management aspects of an element (typically a system or " |
|
"device). The element\'s power management capabilities are " |
|
"decoupled from a PowerManagementService, since a single " |
|
"service could apply to multiple elements, each with specific " |
|
"capabilities." )] |
|
class CIM_PowerManagementCapabilities : CIM_Capabilities { |
|
|
|
[Description ( |
|
"An enumeration indicating the specific power-related " |
|
"capabilities of a managed element. Since this is an " |
|
"array, multiple values may be specified. The current " |
|
"values in the enumeration are: \n" |
|
"0 = Unknown \n" |
|
"1 = Other \n" |
|
"2 = Power Saving Modes Entered Automatically, describing " |
|
"that a managed element can change its power state based " |
|
"on usage or other criteria \n" |
|
"3 = Power State Settable, indicating that the " |
|
"SetPowerState method is supported \n" |
|
"4 = Power Cycling Supported, indicating that the " |
|
"SetPowerState method can be invoked with the PowerState " |
|
"input variable set to \'Power Cycle\' \n" |
|
"5 = Timed Power On Supported, indicating that the " |
|
"SetPowerState method can be invoked with the PowerState " |
|
"input variable set to \'Power Cycle\' and the Time " |
|
"parameter set to a specific date and time, or interval, " |
|
"for power-on." ), |
|
ValueMap { "0", "1", "2", "3", "4", "5" }, |
|
Values { "Unknown", "Other", |
|
"Power Saving Modes Entered Automatically", |
|
"Power State Settable", "Power Cycling Supported", |
|
"Timed Power On Supported" }, |
|
MappingStrings { "MIF.DMTF|System Power Controls|001.2" }, |
|
ModelCorrespondence { |
|
"CIM_PowerManagementCapabilities.OtherPowerCapabilitiesDescriptions", |
|
"CIM_PowerManagementService.SetPowerState" }] |
|
uint16 PowerCapabilities[]; |
|
|
|
[Description ( |
|
"An array of strings describing an element\'s additional " |
|
"power management capabilities, used when the " |
|
"PowerCapabilities array includes the value 1, \"Other\"." ), |
|
ModelCorrespondence { |
|
"CIM_PowerManagementCapabilities.PowerCapabilities" }] |
|
string OtherPowerCapabilitiesDescriptions[]; |
|
|
|
[Description ( |
|
"An enumeration that indicates the power states supported " |
|
"by a managed element. Because this is an array, multiple " |
|
"values can be specified. The current values in the " |
|
"enumeration are: \n" |
|
"2=On, corresponding to ACPI state G0 or S0 or D0. \n" |
|
"3=Sleep - Light, corresponding to ACPI state G1, S1/S2, " |
|
"or D1. \n" |
|
"4=Sleep - Deep, corresponding to ACPI state G1, S3, or D2.\n" |
|
"5=Power Cycle (Off - Soft), corresponding to ACPI state " |
|
"G2, S5, or D3, but where the managed element is set to " |
|
"return to power state \"On\" at a pre-determined time. \n" |
|
"6=Off - Hard, corresponding to ACPI state G3, S5, or D3. \n" |
|
"7=Hibernate (Off - Soft), corresponding to ACPI state " |
|
"S4, where the state of the managed element is preserved " |
|
"and will be recovered upon powering on. \n" |
|
"8=Off - Soft, corresponding to ACPI state G2, S5, or D3. " |
|
"9= Power Cycle (Off-Hard), corresponds to the managed " |
|
"element reaching the ACPI state G3 followed by ACPI " |
|
"state S0. \n" |
|
"10=Master Bus Reset, corresponds to the system reaching " |
|
"ACPI state S5 followed by ACPI state S0. This is used to " |
|
"represent system master bus reset. 11=Diagnostic " |
|
"Interrupt (NMI), corresponding to the system reaching " |
|
"ACPI state S5 followed by ACPI state S0. This is used to " |
|
"represent system non-maskable interrupt. 12=Off - Soft " |
|
"Graceful, equivalent to Off Soft but preceded by a " |
|
"request to the managed element to perform an " |
|
"orderlyshutdown. \n" |
|
"13=Off - Hard Graceful, equivalent to Off Hard but " |
|
"preceded by a request to the managed element to perform " |
|
"an orderly shutdown. \n" |
|
"14=Master Bus Rest Graceful, equivalent to Master Bus " |
|
"Reset but preceded by a request to the managed element " |
|
"to perform an orderly shutdown. \n" |
|
"15=Power Cycle (Off - Soft Graceful), equivalent to " |
|
"Power Cycle (Off - Soft) but preceded by a request to " |
|
"the managed element to perform an orderly shutdown. \n" |
|
"16=Power Cycle (Off - Hard Graceful), equivalent to " |
|
"Power Cycle (Off - Hard) but preceded by a request to " |
|
"the managed element to perform an orderly shutdown. \n" |
|
"..=DMTF Reserved. \n" |
|
"0x7FFF..0xFFFF = Vendor Specific." ), |
|
ValueMap { "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", |
|
"11", "12", "13", "14", "15", "16", "..", "0x7FFF..0xFFFF" }, |
|
Values { "Other", "On", "Sleep - Light", "Sleep -Deep", |
|
"Power Cycle (Off - Soft)", "Off - Hard", |
|
"Hibernate (Off - Soft)", "Off - Soft", |
|
"Power Cycle (Off-Hard)", "Master Bus Reset", |
|
"Diagnostic Interrupt (NMI)", "Off - Soft Graceful", |
|
"Off - Hard Graceful", "Master Bus Reset Graceful", |
|
"Power Cycle (Off - Soft Graceful)", |
|
"Power Cycle (Off - Hard Graceful)", "DMTF Reserved", |
|
"Vendor Specific" }, |
|
MappingStrings { "IEEE P1621 | 3.2" }, |
|
ModelCorrespondence { |
|
"CIM_PowerManagementService.RequestPowerStateChange", |
|
"CIM_AssociatedPowerManagementService.PowerState" }] |
|
uint16 PowerStatesSupported[]; |
|
|
|
[Description ( |
|
"An enumeration indicating the specific power-related " |
|
"capabilities of a managed element. Since this is an " |
|
"array, multiple values may be specified. The current " |
|
"values in the enumeration are: \n" |
|
"0 = Unknown \n" |
|
"1 = Other \n" |
|
"2 = Power Saving Modes Entered Automatically, describing " |
|
"that a managed element can change its power state based " |
|
"on usage or other criteria \n" |
|
"3 = Power State Settable, indicating that the " |
|
"RequestPowerStateChange method is supported \n" |
|
"4 = Power Cycling Supported, indicating that the " |
|
"RequestPowerStateChange method can be invoked with the " |
|
"PowerState input variable set to \'Power Cycle (Off " |
|
"Soft)\' \n" |
|
"5 = Timed Power On Supported, indicating that the " |
|
"RequestPowerStateChange method can be invoked with the " |
|
"PowerState input variable set to \'Power On\' and the " |
|
"Time parameter set to a specific date and time, or " |
|
"interval, for power-on.8 = Graceful Shutdown Supported, " |
|
"indicating that the managed element can be sent a " |
|
"hardware signal requesting an orderly shutdown prior to " |
|
"the requested power state change." ), |
|
ValueMap { "0", "1", "2", "3", "4", "5", "6", "7", "8" }, |
|
Values { "Unknown", "Other", |
|
"Power Saving Modes Entered Automatically", |
|
"Power State Settable", "Power Cycling Supported", |
|
"Timed Power On Supported", |
|
"Off Hard Power Cycling Supported", "HW Reset Supported", |
|
"Graceful Shutdown Supported" }, |
|
ModelCorrespondence { |
|
"CIM_PowerManagementService.RequestPowerStateChange", |
|
"CIM_PowerManagementCapabilities.OtherPowerChangeCapabilities" }] |
|
uint16 PowerChangeCapabilities[]; |
|
|
|
[Description ( |
|
"A string describing the additional power management " |
|
"capabilities of the element, used when the " |
|
"PowerChangeCapabilities is set to the value 1, \"Other\"." ), |
|
ModelCorrespondence { |
|
"CIM_PowerManagementCapabilities.PowerChangeCapabilities" }] |
|
string OtherPowerChangeCapabilities; |
|
|
|
[Description ( |
|
"An enumeration that indicates the requested power states " |
|
"supported by the power management service. Because this " |
|
"is an array, multiple values can be specified. The " |
|
"current values in the enumeration are: \n" |
|
"2=On, corresponding to ACPI state G0 or S0 or D0. \n" |
|
"3=Sleep - Light, corresponding to ACPI state G1, S1/S2, " |
|
"or D1. \n" |
|
"4=Sleep - Deep, corresponding to ACPI state G1, S3, or D2.\n" |
|
"5=Power Cycle (Off - Soft), corresponding to ACPI state " |
|
"G2, S5, or D3, but where the managed element is set to " |
|
"return to power state \"On\" at a pre-determined time. \n" |
|
"6=Off - Hard, corresponding to ACPI state G3, S5, or D3. \n" |
|
"7=Hibernate (Off - Soft), corresponding to ACPI state " |
|
"S4, where the state of the managed element is preserved " |
|
"and will be recovered upon powering on. \n" |
|
"8=Off - Soft, corresponding to ACPI state G2, S5, or D3. " |
|
"9= Power Cycle (Off-Hard), corresponds to the managed " |
|
"element reaching the ACPI state G3 followed by ACPI " |
|
"state S0. \n" |
|
"10=Master Bus Reset, corresponds to the system reaching " |
|
"ACPI state S5 followed by ACPI state S0. This is used to " |
|
"represent system master bus reset. 11=Diagnostic " |
|
"Interrupt (NMI), corresponding to the system reaching " |
|
"ACPI state S5 followed by ACPI state S0. This is used to " |
|
"represent system non-maskable interrupt. 12=Off - Soft " |
|
"Graceful, equivalent to Off Soft but preceded by a " |
|
"request to the managed element to perform an " |
|
"orderlyshutdown. \n" |
|
"13=Off - Hard Graceful, equivalent to Off Hard but " |
|
"preceded by a request to the managed element to perform " |
|
"an orderly shutdown. \n" |
|
"14=Master Bus Rest Graceful, equivalent to Master Bus " |
|
"Reset but preceded by a request to the managed element " |
|
"to perform an orderly shutdown. \n" |
|
"15=Power Cycle (Off - Soft Graceful), equivalent to " |
|
"Power Cycle (Off - Soft) but preceded by a request to " |
|
"the managed element to perform an orderly shutdown. \n" |
|
"16=Power Cycle (Off - Hard Graceful), equivalent to " |
|
"Power Cycle (Off - Hard) but preceded by a request to " |
|
"the managed element to perform an orderly shutdown. \n" |
|
"17=Diagnostic Interrupt (INIT), equivalent to Diagnostic " |
|
"Interrupt (NMI) but performed by an INIT switch instead " |
|
"because the NMI signal is masked. \n" |
|
"..=DMTF Reserved. \n" |
|
"0x7FFF..0xFFFF = Vendor Specific." ), |
|
ValueMap { "1", "2", "3", "4", "5", "6", "7", "8", "9", "10", |
|
"11", "12", "13", "14", "15", "16", "17", "..", |
|
"0x7FFF..0xFFFF" }, |
|
Values { "Other", "On", "Sleep - Light", "Sleep -Deep", |
|
"Power Cycle (Off - Soft)", "Off - Hard", |
|
"Hibernate (Off - Soft)", "Off - Soft", |
|
"Power Cycle (Off-Hard)", "Master Bus Reset", |
|
"Diagnostic Interrupt (NMI)", "Off - Soft Graceful", |
|
"Off - Hard Graceful", "Master Bus Reset Graceful", |
|
"Power Cycle (Off - Soft Graceful)", |
|
"Power Cycle (Off - Hard Graceful)", |
|
"Diagnostic Interrupt (INIT)", "DMTF Reserved", |
|
"Vendor Specific" }, |
|
MappingStrings { "IEEE P1621 | 3.2" }, |
|
ModelCorrespondence { |
|
"CIM_PowerManagementCapabilities.PowerStatesSupported", |
|
"CIM_PowerManagementService.RequestPowerStateChange", |
|
"CIM_AssociatedPowerManagementService.PowerState" }] |
|
uint16 RequestedPowerStatesSupported[]; |
|
|
|
|
|
}; |